Boards made from recycled laminated cartons (e.g. Tetra Pak) can be used as an alternative to traditional materials (e.g. gypsum boards or oriented strand boards) used nowadays in the sandwich building envelope. This paper presents a methodology and results of a long-term experiment with prefab sandwich facade-panels (made of these boards) exposed to real exterior conditions. Altogether 15 facade-panel samples were used divided into 3 sets ? reference set (not exposed), set 1 (exposed for 27 months), and set 2 (exposed for 43 months). The samples within the sets differed in external plastering. The samples of size 500 x 500 mm were placed in a wooden grid that was placed vertically on the roof of the Faculty of Civil Engineering Czech Technical University in Prague facing towards the south. Throughout the experiment there were monitored basic climatic data near the testing grid and concurrently the surface temperature was measured on samples. The progress of the experiment was document
Název v anglickém jazyce
The Use of Boards from Recycled Laminated Cartons in The Building Envelope
Popis výsledku anglicky
Boards made from recycled laminated cartons (e.g. Tetra Pak) can be used as an alternative to traditional materials (e.g. gypsum boards or oriented strand boards) used nowadays in the sandwich building envelope. This paper presents a methodology and results of a long-term experiment with prefab sandwich facade-panels (made of these boards) exposed to real exterior conditions. Altogether 15 facade-panel samples were used divided into 3 sets ? reference set (not exposed), set 1 (exposed for 27 months), and set 2 (exposed for 43 months). The samples within the sets differed in external plastering. The samples of size 500 x 500 mm were placed in a wooden grid that was placed vertically on the roof of the Faculty of Civil Engineering Czech Technical University in Prague facing towards the south. Throughout the experiment there were monitored basic climatic data near the testing grid and concurrently the surface temperature was measured on samples. The progress of the experiment was document
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CESB 13 - Central Europe towards Sustainable Building 2013
ISBN
978-80-247-5018-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
349-352
Název nakladatele
GRADA PUBLISHING
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
26. 6. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—