Analysis of the shear cracks in the prestressed thin-wall element and their effect on the deflection of the structure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F13%3A00208166" target="_blank" >RIV/68407700:21110/13:00208166 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of the shear cracks in the prestressed thin-wall element and their effect on the deflection of the structure
Popis výsledku v původním jazyce
Nowadays, more emphasis is placed on reducing of economic efficiency of structures and reducing their negative impact on the environment. This leads to the effort of the reducing their own weight, especially in the big-span structures (such as bridges).The self weight is the major part of the total load in this type of structures. The use of the thin prestressed elements is advantage in this case. Their deflections can be effectively eliminated by correct prestressing arrangement. The right prestressing arrangement also ensures avoiding of bending cracks and reducing bending stiffness. High attention must be given to the shear capacity of these elements and creation of the shear cracks. These cracks influence the behavior of the whole structure. Thispaper is focused on monitoring the initiation and development of the shear cracks in thinweb prestressed concrete elements. Their influence on the development of deflection is also examined.
Název v anglickém jazyce
Analysis of the shear cracks in the prestressed thin-wall element and their effect on the deflection of the structure
Popis výsledku anglicky
Nowadays, more emphasis is placed on reducing of economic efficiency of structures and reducing their negative impact on the environment. This leads to the effort of the reducing their own weight, especially in the big-span structures (such as bridges).The self weight is the major part of the total load in this type of structures. The use of the thin prestressed elements is advantage in this case. Their deflections can be effectively eliminated by correct prestressing arrangement. The right prestressing arrangement also ensures avoiding of bending cracks and reducing bending stiffness. High attention must be given to the shear capacity of these elements and creation of the shear cracks. These cracks influence the behavior of the whole structure. Thispaper is focused on monitoring the initiation and development of the shear cracks in thinweb prestressed concrete elements. Their influence on the development of deflection is also examined.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PhD Workshop
ISBN
978-80-01-05236-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze, Fakulta stavební
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
24. 5. 2013
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—