Verification of compressive strength on different sized hsc specimens
Popis výsledku v původním jazyce
HPC and UHPC concretes are getting employed more and more often in civil engineering structures. These concretes are characterized mainly by its high compressive strength. Destructive testing on specimens 150/150/150 mm according to ČSN EN 206 is very demanding with respect to the equipment of the laboratory. To crush UHPC cube with 160 MPa compressive strength, the force of circa 3600 kN is required. The specimens produced sometimes reach 200 MPa strength. In this paper, the results of research focusedon determination of compressive strength on HSC cubes of different edge sizes will be presented. The concrete mix tested is called HSC (not HPC), because no properties other than compressive strength were measured. The composition of concrete was intentionally modified to decrease the compressive strength of some specimens under 160 MPa.
Název v anglickém jazyce
Verification of compressive strength on different sized hsc specimens
Popis výsledku anglicky
HPC and UHPC concretes are getting employed more and more often in civil engineering structures. These concretes are characterized mainly by its high compressive strength. Destructive testing on specimens 150/150/150 mm according to ČSN EN 206 is very demanding with respect to the equipment of the laboratory. To crush UHPC cube with 160 MPa compressive strength, the force of circa 3600 kN is required. The specimens produced sometimes reach 200 MPa strength. In this paper, the results of research focusedon determination of compressive strength on HSC cubes of different edge sizes will be presented. The concrete mix tested is called HSC (not HPC), because no properties other than compressive strength were measured. The composition of concrete was intentionally modified to decrease the compressive strength of some specimens under 160 MPa.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Fibre Concrete .2013 - Technology, Design, Application
ISBN
978-80-01-05240-2
ISSN
2336-338X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
47-52
Název nakladatele
České vysoké učení technické v Praze, Fakulta stavební
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
12. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—