Ecological aspect in combined sewer overflows chamber design
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F13%3A00215227" target="_blank" >RIV/68407700:21110/13:00215227 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21110/14:00227219
Výsledek na webu
<a href="http://www.iwaponline.com/wpt/008/0041/0080041.pdf" target="_blank" >http://www.iwaponline.com/wpt/008/0041/0080041.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ecological aspect in combined sewer overflows chamber design
Popis výsledku v původním jazyce
In 2005 one of major Czech manufacturers of glass reinforced plastic pipes asked the Department of Sanitary and Ecological Engineering to develop a new type of combined sewer overflows (CSO) chamber that could become a part of their manufacturing programme. The main requirements were economy of production, easy and fast installation on the field and increased protection of receiving waters. A simple object consisting of a pipe placed above another one was designed. The object begins with a stilling chamber formed by a conical expansion of the inlet pipe. It is separated from the overflow object itself by a downflow baffle designed to trap floating objects. The CSO chamber is equipped by a flow regulation device (e.g. vortex valve or throttle pipe) at the end. Excess water flows through a slit in the top of the bottom pipe into the upper pipe and from there to the receiving water. More than 15 prototypes were already installed in the Czech and Slovak Republics and more than 20 are plann
Název v anglickém jazyce
Ecological aspect in combined sewer overflows chamber design
Popis výsledku anglicky
In 2005 one of major Czech manufacturers of glass reinforced plastic pipes asked the Department of Sanitary and Ecological Engineering to develop a new type of combined sewer overflows (CSO) chamber that could become a part of their manufacturing programme. The main requirements were economy of production, easy and fast installation on the field and increased protection of receiving waters. A simple object consisting of a pipe placed above another one was designed. The object begins with a stilling chamber formed by a conical expansion of the inlet pipe. It is separated from the overflow object itself by a downflow baffle designed to trap floating objects. The CSO chamber is equipped by a flow regulation device (e.g. vortex valve or throttle pipe) at the end. Excess water flows through a slit in the top of the bottom pipe into the upper pipe and from there to the receiving water. More than 15 prototypes were already installed in the Czech and Slovak Republics and more than 20 are plann
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA02020169" target="_blank" >TA02020169: Aplikovaný výzkum vybraných objektů stokových sítí: zvýšení kvantitativní a kvalitativní účinnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Water Practice & Technology
ISSN
1751-231X
e-ISSN
—
Svazek periodika
2013
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
409-416