Hygrothermal performance of hollow brick with foam polyurethane cavity filler
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00218237" target="_blank" >RIV/68407700:21110/14:00218237 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hygrothermal performance of hollow brick with foam polyurethane cavity filler
Popis výsledku v původním jazyce
Hygrothermal performance of newly developed type of hollow brick is studied in the difference climate conditions. The cavities of hollow brick are filled by foam polyurethane (PU). The experiment is done in semi-scale conditions. For that purpose, a system of two climatic chambers separated by the connecting tunnel for sample positioning is used. The studied brick block is provided with combined temperature/relative humidity sensors and thermally and vapour proof insulated in the tunnel between the climatic chambers. In the interior climatic chamber, constant temperature and relative humidity values typical for residential houses are set. On the exterior side, there are simulated hourly data of relative humidity and temperature corresponding to Pragueclimatic reference year. In this way, the 1-D heat and water vapour flux through the studied brick block is simulated. The obtained data provide a detailed information on the hygrothermal performance of the analyzed brick exposed to winte
Název v anglickém jazyce
Hygrothermal performance of hollow brick with foam polyurethane cavity filler
Popis výsledku anglicky
Hygrothermal performance of newly developed type of hollow brick is studied in the difference climate conditions. The cavities of hollow brick are filled by foam polyurethane (PU). The experiment is done in semi-scale conditions. For that purpose, a system of two climatic chambers separated by the connecting tunnel for sample positioning is used. The studied brick block is provided with combined temperature/relative humidity sensors and thermally and vapour proof insulated in the tunnel between the climatic chambers. In the interior climatic chamber, constant temperature and relative humidity values typical for residential houses are set. On the exterior side, there are simulated hourly data of relative humidity and temperature corresponding to Pragueclimatic reference year. In this way, the 1-D heat and water vapour flux through the studied brick block is simulated. The obtained data provide a detailed information on the hygrothermal performance of the analyzed brick exposed to winte
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI3%2F085" target="_blank" >FR-TI3/085: Energeticky úsporné cihlové budovy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10th Nordic Symposium on Building Physics
ISBN
978-91-88722-53-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
354-361
Název nakladatele
Lund University
Místo vydání
Lund
Místo konání akce
Lund
Datum konání akce
15. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—