Effect of Porosity on Mechanical and Hygric Properties of Concrete with Natural Pozzolan Addition
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00219394" target="_blank" >RIV/68407700:21110/14:00219394 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26110/14:PU110678
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.982.22" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.982.22</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.982.22" target="_blank" >10.4028/www.scientific.net/AMR.982.22</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of Porosity on Mechanical and Hygric Properties of Concrete with Natural Pozzolan Addition
Popis výsledku v původním jazyce
Effect of porosity on mechanical and hygric properties of high performance concrete (HPC) with natural pozzolan as partial Portland cement replacement up to 40% is studied in the paper. The reference HPC mixture is researched as well in order to evaluatethe influence of pozzolan usage on concrete performance. For the studied materials, measurement of compressive strength, sorptivity, apparent moisture diffusivity, and water vapor diffusion permeability is done. The obtained data shows that applicationof the pozzolan as partial cement replacement leads to increase of concrete porosity that is related to the lower mechanical strength and higher monture transport properties. Therefore, the applied natural pozzolan has a potential to replace a part of Portland cement in concrete manufacturing but its content in concrete mixture has strict limitations.
Název v anglickém jazyce
Effect of Porosity on Mechanical and Hygric Properties of Concrete with Natural Pozzolan Addition
Popis výsledku anglicky
Effect of porosity on mechanical and hygric properties of high performance concrete (HPC) with natural pozzolan as partial Portland cement replacement up to 40% is studied in the paper. The reference HPC mixture is researched as well in order to evaluatethe influence of pozzolan usage on concrete performance. For the studied materials, measurement of compressive strength, sorptivity, apparent moisture diffusivity, and water vapor diffusion permeability is done. The obtained data shows that applicationof the pozzolan as partial cement replacement leads to increase of concrete porosity that is related to the lower mechanical strength and higher monture transport properties. Therefore, the applied natural pozzolan has a potential to replace a part of Portland cement in concrete manufacturing but its content in concrete mixture has strict limitations.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-04522S" target="_blank" >GA14-04522S: Výzkum procesů při vytváření pevné struktury v soustavě oxid křemičitý-portlandský cement ve vztahu k vlastnostem pojiva</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Mechanical, Thermal and Hygric Properties of Buildings Materials
ISBN
978-3-03835-172-6
ISSN
1022-6680
e-ISSN
—
Počet stran výsledku
5
Strana od-do
22-26
Název nakladatele
TRANS TECH PUBLICATIONS LTD
Místo vydání
ZURICH
Místo konání akce
Zahrádky
Datum konání akce
23. 7. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—