Testing Electronic Distance Meters on Short Absolute Laboratory Baseline
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00219939" target="_blank" >RIV/68407700:21110/14:00219939 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Testing Electronic Distance Meters on Short Absolute Laboratory Baseline
Popis výsledku v původním jazyce
The paper deals with testing of electronic distance meters (EDM) on absolute laboratory baseline. The EDM baseline is made up of 16 concrete pillars with forced centering and its length is 38.6 m. It is used in accordance with the rules for very precisemeasurement. To determine the coordinates and distances between pillars, very accurate industrial instrument, Leica Absolute Tracker AT401 was used (accuracy of distance measurement: 10 ?m, accuracy of direction measurement: 0.15 mgon). The coordinates were determined by adjustment of polar measurement from 3 pillars. The lengths between pillars were determined with an accuracy of 0.02 mm. The baseline is used for testing EDMs of total stations that are used for accurate measurement for purposes of mechanical engineering. The EDMs were tested to determine the sizes of systematic and random errors on short distances which are common in engineering surveying. Repeated measurements were also used to determine time stability of the errors o
Název v anglickém jazyce
Testing Electronic Distance Meters on Short Absolute Laboratory Baseline
Popis výsledku anglicky
The paper deals with testing of electronic distance meters (EDM) on absolute laboratory baseline. The EDM baseline is made up of 16 concrete pillars with forced centering and its length is 38.6 m. It is used in accordance with the rules for very precisemeasurement. To determine the coordinates and distances between pillars, very accurate industrial instrument, Leica Absolute Tracker AT401 was used (accuracy of distance measurement: 10 ?m, accuracy of direction measurement: 0.15 mgon). The coordinates were determined by adjustment of polar measurement from 3 pillars. The lengths between pillars were determined with an accuracy of 0.02 mm. The baseline is used for testing EDMs of total stations that are used for accurate measurement for purposes of mechanical engineering. The EDMs were tested to determine the sizes of systematic and random errors on short distances which are common in engineering surveying. Repeated measurements were also used to determine time stability of the errors o
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DE - Zemský magnetismus, geodesie, geografie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
14th International Multidisciplinary Scientific Geoconference SGEM 2014 - Informatics, Geoinformatics and Remote Sensing - Conference Proceedings Volume II - Geodesy & Mine Surveying
ISBN
978-619-7105-11-7
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
8
Strana od-do
497-504
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Albena
Datum konání akce
17. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—