Utilization of fly ash in massive concrete structures ? temperature evolution and multiscale modeling
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00220914" target="_blank" >RIV/68407700:21110/14:00220914 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of fly ash in massive concrete structures ? temperature evolution and multiscale modeling
Popis výsledku v původním jazyce
Massive concrete structures generally suffer from excessive hydration heat which results in formidable high temperatures. Fly ash presents a powerful method of reducing the amount of Portland clinker, resulting in lower temperatures and lower autogeneousshrinkage. In this paper, we demonstrate application of fly ash in Czech structures built from concretes C8/10 - C25/30 since 1960s up today. Temperature evolution is validated via multiscale model that further leads to a nomogram for general concrete massive structures. The nomogram predicts maximum concrete temperature depending on the type and the amount of a binder, added fly ash, member thickness, initial concrete temperature and ambient temperature. Performance of massive concrete structures containing fly ash demonstrates suitable utilization of fly ash in large quantities.
Název v anglickém jazyce
Utilization of fly ash in massive concrete structures ? temperature evolution and multiscale modeling
Popis výsledku anglicky
Massive concrete structures generally suffer from excessive hydration heat which results in formidable high temperatures. Fly ash presents a powerful method of reducing the amount of Portland clinker, resulting in lower temperatures and lower autogeneousshrinkage. In this paper, we demonstrate application of fly ash in Czech structures built from concretes C8/10 - C25/30 since 1960s up today. Temperature evolution is validated via multiscale model that further leads to a nomogram for general concrete massive structures. The nomogram predicts maximum concrete temperature depending on the type and the amount of a binder, added fly ash, member thickness, initial concrete temperature and ambient temperature. Performance of massive concrete structures containing fly ash demonstrates suitable utilization of fly ash in large quantities.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP104%2F12%2F0102" target="_blank" >GAP104/12/0102: Alumosilikátové polymerní pěny</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EuroCoalAsh 2014 - Conference Proceedings
ISBN
978-3-86875-805-4
ISSN
—
e-ISSN
—
Počet stran výsledku
12
Strana od-do
119-130
Název nakladatele
VGB PowerTech e.V.
Místo vydání
Essen
Místo konání akce
Mnichov
Datum konání akce
13. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—