Numerical analysis of layered UHPFRC-SHCC structural elements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00224192" target="_blank" >RIV/68407700:21110/14:00224192 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical analysis of layered UHPFRC-SHCC structural elements
Popis výsledku v původním jazyce
Mechanical behavior of layered systems, in which high-strength UHPFRC with steel fibers is used to provide load bearing function and ductile SHCC with PVA fibers should serve as a durable corrosion-resistant coating, is examined by FEM. A variant, wherethe coating consists of quasi-brittle UHPC lacking any fiber reinforcement is also tested as a reference. Simulated experiments include three point bending of a plate and a thermal shock test of a facade panel. The results indicate advantages of using SHCC over UHPC, namely as applying the former results in higher displacement capacity of the plates, smaller crack width and smaller interfacial stresses. Performance of SHCC coating under thermal shock also meets requirements. The study thus provides an impetus for further testing and development of the technology of UHPFRC-SHCC layered elements.
Název v anglickém jazyce
Numerical analysis of layered UHPFRC-SHCC structural elements
Popis výsledku anglicky
Mechanical behavior of layered systems, in which high-strength UHPFRC with steel fibers is used to provide load bearing function and ductile SHCC with PVA fibers should serve as a durable corrosion-resistant coating, is examined by FEM. A variant, wherethe coating consists of quasi-brittle UHPC lacking any fiber reinforcement is also tested as a reference. Simulated experiments include three point bending of a plate and a thermal shock test of a facade panel. The results indicate advantages of using SHCC over UHPC, namely as applying the former results in higher displacement capacity of the plates, smaller crack width and smaller interfacial stresses. Performance of SHCC coating under thermal shock also meets requirements. The study thus provides an impetus for further testing and development of the technology of UHPFRC-SHCC layered elements.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-15175S" target="_blank" >GA13-15175S: Prvky z funkčně vrstvených vláknocementových kompozitů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
3rd International RILEM Conference on Strain Hardening Cementitious Composites (SHCC3-Delft)
ISBN
978-2-35158-150-6
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
211-218
Název nakladatele
Rilem Publications s.a.r.l.
Místo vydání
Bagneux
Místo konání akce
Dordrecht
Datum konání akce
3. 11. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—