Estimating the input parameters of lumped building thermal models on the basis of standard design values
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00227551" target="_blank" >RIV/68407700:21110/14:00227551 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Estimating the input parameters of lumped building thermal models on the basis of standard design values
Popis výsledku v původním jazyce
This paper focuses on testing whether the input parameters of lumped parameter building thermal models could be estimated in advance on the basis of the known geometry and envelope composition of the building. The study was performed using a virtual testfamily house insulated in a low-energy standard. Two variants of the house were defined: a light one, made of timber structure, and the a heavier one, made of perforated brick blocks with external insulation. The reference results were calculated usinga complex building energy simulation model. Then, simulations using four logical structures of lumped parameter models were conducted. The values of the lumped parameters in these models were estimated on the basis of available information on the test building, i.e. on the basis of basic drawings and known composition of building components. The results achieved on the lumped models were then compared with the reference solution. The results of this study show that input parameters of lu
Název v anglickém jazyce
Estimating the input parameters of lumped building thermal models on the basis of standard design values
Popis výsledku anglicky
This paper focuses on testing whether the input parameters of lumped parameter building thermal models could be estimated in advance on the basis of the known geometry and envelope composition of the building. The study was performed using a virtual testfamily house insulated in a low-energy standard. Two variants of the house were defined: a light one, made of timber structure, and the a heavier one, made of perforated brick blocks with external insulation. The reference results were calculated usinga complex building energy simulation model. Then, simulations using four logical structures of lumped parameter models were conducted. The values of the lumped parameters in these models were estimated on the basis of available information on the test building, i.e. on the basis of basic drawings and known composition of building components. The results achieved on the lumped models were then compared with the reference solution. The results of this study show that input parameters of lu
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10th Nordic Symposium on Building Physics
ISBN
978-91-88722-53-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
742-749
Název nakladatele
Lund University
Místo vydání
Lund
Místo konání akce
Lund
Datum konání akce
15. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—