Measurement of Frost Resistance of Cement Concrete with Fly Ash
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00230521" target="_blank" >RIV/68407700:21110/15:00230521 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/15:00230521
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Frost Resistance of Cement Concrete with Fly Ash
Popis výsledku v původním jazyce
Fly ash is due to its pozzolanic properties commonly used as the active component of concrete. This obviously has effect on the properties of the resulting material. One of the most important indicators of the quality of the material is its durability. The basic parameter of durability is a frost resistance. There are several approaches to measuring the frost resistance in the Czech Republic. This paper deals with a summary of these procedures and their pitfalls. Furthermore, the article provides examples of measurement ? from the practice concrete of Orlik Dam. Literature shows the effect of fly ash on the frost resistance of the resulting concrete as ambivalent. When measuring the frost resistance of concrete with fly ash it is very important to takeaccount of the measuring method, type of the fly ash and the degree of substitution clinker.
Název v anglickém jazyce
Measurement of Frost Resistance of Cement Concrete with Fly Ash
Popis výsledku anglicky
Fly ash is due to its pozzolanic properties commonly used as the active component of concrete. This obviously has effect on the properties of the resulting material. One of the most important indicators of the quality of the material is its durability. The basic parameter of durability is a frost resistance. There are several approaches to measuring the frost resistance in the Czech Republic. This paper deals with a summary of these procedures and their pitfalls. Furthermore, the article provides examples of measurement ? from the practice concrete of Orlik Dam. Literature shows the effect of fly ash on the frost resistance of the resulting concrete as ambivalent. When measuring the frost resistance of concrete with fly ash it is very important to takeaccount of the measuring method, type of the fly ash and the degree of substitution clinker.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Experimental Stress Analysis 2015
ISBN
978-80-01-05734-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
488-491
Název nakladatele
České vysoké učení technické v Praze, Fakulta stavební
Místo vydání
Praha
Místo konání akce
Český Krumlov
Datum konání akce
1. 6. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—