Popis výsledku v původním jazyce
Modeling and characterization of material interfaces is necessary for design and verification of layered FRCCsystems, such as functionally graded structural members. The main objective of the present study is to analyze, by means of numerical simulations, experimental configurations that could be used to identify the mechanical parameters of interfaces. Namely, the shear beam and shear box tests are studied. The results indicate that while the shear beam tests are suitable for identification of the interface strength parameters, they do not provide data necessary for calibration of the post-failure cohesive relationship. The shear box test is not suitable for evaluation of the interface strength parameters as the failure is initiated by localized stress concentration. The post-failure response is governed by sliding of the interface, however even in this phase non-uniformity of the interfacial tractions should be taken into account.
Název v anglickém jazyce
Finite element analysis of test configurations for identification of interface parameters in layered FRCC systems
Popis výsledku anglicky
Modeling and characterization of material interfaces is necessary for design and verification of layered FRCCsystems, such as functionally graded structural members. The main objective of the present study is to analyze, by means of numerical simulations, experimental configurations that could be used to identify the mechanical parameters of interfaces. Namely, the shear beam and shear box tests are studied. The results indicate that while the shear beam tests are suitable for identification of the interface strength parameters, they do not provide data necessary for calibration of the post-failure cohesive relationship. The shear box test is not suitable for evaluation of the interface strength parameters as the failure is initiated by localized stress concentration. The post-failure response is governed by sliding of the interface, however even in this phase non-uniformity of the interfacial tractions should be taken into account.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-15175S" target="_blank" >GA13-15175S: Prvky z funkčně vrstvených vláknocementových kompozitů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
HPFRCC-7: Proceedings of the 7th RILEM Workshop on High Performance Fiber Reinforced Cement Composites
ISBN
978-2-35158-145-2
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
425-432
Název nakladatele
Fraunhofer IRB Verlag
Místo vydání
Stuttgart
Místo konání akce
Stuttgart
Datum konání akce
1. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—