Fibre Reinforced Concrete Folded Plate for Railway Lines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00232010" target="_blank" >RIV/68407700:21110/15:00232010 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4203/ccp.108" target="_blank" >http://dx.doi.org/10.4203/ccp.108</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4203/ccp.108" target="_blank" >10.4203/ccp.108</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fibre Reinforced Concrete Folded Plate for Railway Lines
Popis výsledku v původním jazyce
Fibre reinforced concrete (FRC) is a material whose utilization in the concrete industry has been rapidly increasing recently. This paper is focused on the study of FRC use for precast folded plates offered by the company specialized in the area of concrete elements for the railway industry. Nowadays the folded plate is made of conventional reinforced concrete. The aim of the study is to verify the buildability of the modified variant of the folded plate made of self compacted fibre reinforced concrete(SCFRC) without conventional reinforcement instead of reinforced concrete. The paper describes the whole procedure for the design and manufacture of the precast element. Within the scope of work, the design and manufacturing technology of SCFRC is demonstrated, as well as the numerical analysis of fibre reinforced concrete folded plate on a nonlinear model. Three various stages of production (load cases) - dismantling, transport to the building site and intended use were analyzed. Beside
Název v anglickém jazyce
Fibre Reinforced Concrete Folded Plate for Railway Lines
Popis výsledku anglicky
Fibre reinforced concrete (FRC) is a material whose utilization in the concrete industry has been rapidly increasing recently. This paper is focused on the study of FRC use for precast folded plates offered by the company specialized in the area of concrete elements for the railway industry. Nowadays the folded plate is made of conventional reinforced concrete. The aim of the study is to verify the buildability of the modified variant of the folded plate made of self compacted fibre reinforced concrete(SCFRC) without conventional reinforcement instead of reinforced concrete. The paper describes the whole procedure for the design and manufacture of the precast element. Within the scope of work, the design and manufacturing technology of SCFRC is demonstrated, as well as the numerical analysis of fibre reinforced concrete folded plate on a nonlinear model. Three various stages of production (load cases) - dismantling, transport to the building site and intended use were analyzed. Beside
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Fifteenth International Conference on Civil, Structural and Environmental Engineering Computing
ISBN
978-1-905088-63-8
ISSN
1759-3433
e-ISSN
—
Počet stran výsledku
11
Strana od-do
—
Název nakladatele
Civil-Comp Press Ltd
Místo vydání
Stirling
Místo konání akce
Praha
Datum konání akce
1. 9. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—