Use of diffraction grating for measuring the focal length and distortion of optical systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00234280" target="_blank" >RIV/68407700:21110/15:00234280 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1364/AO.54.010200" target="_blank" >http://dx.doi.org/10.1364/AO.54.010200</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/AO.54.010200" target="_blank" >10.1364/AO.54.010200</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of diffraction grating for measuring the focal length and distortion of optical systems
Popis výsledku v původním jazyce
The paper presents experimentally simple, accurate and inexpensive method for measuring the focal length and distortion of optical systems using a diffraction grating. The proposed approach does not require any special components or any expensive equipment. The detailed theoretical analysis is performed, and the estimation of uncertainties is studied as well. Afterwards, the method is demonstrated on a computer simulated situation, exemplified on an experimental measurement, and compared with commercially available measurement devices. It is shown that the method provides sufficiently accurate results for many practical applications; therefore, it is appropriate for a laboratory testing and for an industrial application.
Název v anglickém jazyce
Use of diffraction grating for measuring the focal length and distortion of optical systems
Popis výsledku anglicky
The paper presents experimentally simple, accurate and inexpensive method for measuring the focal length and distortion of optical systems using a diffraction grating. The proposed approach does not require any special components or any expensive equipment. The detailed theoretical analysis is performed, and the estimation of uncertainties is studied as well. Afterwards, the method is demonstrated on a computer simulated situation, exemplified on an experimental measurement, and compared with commercially available measurement devices. It is shown that the method provides sufficiently accurate results for many practical applications; therefore, it is appropriate for a laboratory testing and for an industrial application.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Optics
ISSN
1559-128X
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
34
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
10200-10206
Kód UT WoS článku
000366604800026
EID výsledku v databázi Scopus
—