Strengthening of damaged historic vault structures in the Premonstrate Monastery at Teplá with composites based on high-strength fibres and epoxy resin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00239531" target="_blank" >RIV/68407700:21110/15:00239531 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Strengthening of damaged historic vault structures in the Premonstrate Monastery at Teplá with composites based on high-strength fibres and epoxy resin
Popis výsledku v původním jazyce
The on-going conservation and reconstruction of the Premonstrate Monastery at Teplá in western Bohemia was the site for the implementation of the results of research into the application of carbon composites in the rehabilitation of historic vaults. The analysis manifested the occurrence of relatively high tensile stresses at the vault crown in the vault cross section’s parts adjoining the vault soffit due to vertical loading and temperature effects. They exceed the ultimate strength of masonry in tension and may be the cause of the appearance of tensile cracks. The paper presents the design and execution of the stabilisation and reinforcement pro-cedure of vaults over the arcaded walk in the convent on the 1st overground storey, damaged by a continuous, at places prominent, tensile crack at the vault crown using non-prestresed strips of carbon composites and epoxy resin, including the results of FEM numerical analysis and ex-perimental verification.
Název v anglickém jazyce
Strengthening of damaged historic vault structures in the Premonstrate Monastery at Teplá with composites based on high-strength fibres and epoxy resin
Popis výsledku anglicky
The on-going conservation and reconstruction of the Premonstrate Monastery at Teplá in western Bohemia was the site for the implementation of the results of research into the application of carbon composites in the rehabilitation of historic vaults. The analysis manifested the occurrence of relatively high tensile stresses at the vault crown in the vault cross section’s parts adjoining the vault soffit due to vertical loading and temperature effects. They exceed the ultimate strength of masonry in tension and may be the cause of the appearance of tensile cracks. The paper presents the design and execution of the stabilisation and reinforcement pro-cedure of vaults over the arcaded walk in the convent on the 1st overground storey, damaged by a continuous, at places prominent, tensile crack at the vault crown using non-prestresed strips of carbon composites and epoxy resin, including the results of FEM numerical analysis and ex-perimental verification.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
AL - Umění, architektura, kulturní dědictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/DF12P01OVV037" target="_blank" >DF12P01OVV037: Progresivní neinvazivní metody stabilizace, konzervace a zpevňování historických konstrukcí a jejich částí kompozitními materiály na bázi vláken a nanovláken</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
REHAB 2015 - Proceedings of the 2nd International Conference on Preservation, Maintenance and Rehabilitation of Historic Buildings and Structures
ISBN
978-989-8734-10-5
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
311-320
Název nakladatele
Green Lines Institute for Sustainable Development
Místo vydání
Barcelos
Místo konání akce
Porto
Datum konání akce
22. 7. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—