Strengthening of compressed brick masonry walls with carbon composites
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00239963" target="_blank" >RIV/68407700:21110/16:00239963 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0950061816303130" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0950061816303130</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.conbuildmat.2016.03.026" target="_blank" >10.1016/j.conbuildmat.2016.03.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Strengthening of compressed brick masonry walls with carbon composites
Popis výsledku v původním jazyce
In the case of masonry walls reinforced with surface-applied non-prestressed composite strips, experimental research has proved that the reinforcing effect is not unambiguously and expressly positive, unlike the confinement effect of concentrically compressed columns. The paper presents newly obtained findings about the behaviour of brick masonry walls under static loads in their degradation phase in relation to their stabilisation and reinforcement with composites. The analysis is based on the comparison of brick masonry walls with different types of reinforcement. The results of experimental research and their analysis pointed out a series of still open questions concerning the behaviour of masonry in the degradation phase of its mechanical properties.
Název v anglickém jazyce
Strengthening of compressed brick masonry walls with carbon composites
Popis výsledku anglicky
In the case of masonry walls reinforced with surface-applied non-prestressed composite strips, experimental research has proved that the reinforcing effect is not unambiguously and expressly positive, unlike the confinement effect of concentrically compressed columns. The paper presents newly obtained findings about the behaviour of brick masonry walls under static loads in their degradation phase in relation to their stabilisation and reinforcement with composites. The analysis is based on the comparison of brick masonry walls with different types of reinforcement. The results of experimental research and their analysis pointed out a series of still open questions concerning the behaviour of masonry in the degradation phase of its mechanical properties.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/DF12P01OVV037" target="_blank" >DF12P01OVV037: Progresivní neinvazivní metody stabilizace, konzervace a zpevňování historických konstrukcí a jejich částí kompozitními materiály na bázi vláken a nanovláken</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Construction and Building Materials
ISSN
0950-0618
e-ISSN
—
Svazek periodika
112
Číslo periodika v rámci svazku
June
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
1066-1079
Kód UT WoS článku
000375166900113
EID výsledku v databázi Scopus
2-s2.0-84960436376