Beams with corrugated web at elevated temperature, experimental results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00240269" target="_blank" >RIV/68407700:21110/16:00240269 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.tws.2015.02.026" target="_blank" >http://dx.doi.org/10.1016/j.tws.2015.02.026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.tws.2015.02.026" target="_blank" >10.1016/j.tws.2015.02.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Beams with corrugated web at elevated temperature, experimental results
Popis výsledku v původním jazyce
The paper is focused on presenting the thermal and mechanical response of sinusoidal corrugated web beams subjected to high temperatures. Two tests were performed to monitor the behavior of isolated elements and composite slabs designed with corrugated web beams. Different aspect ratio beams exposed to standard fire temperatures and one beam subjected also to mechanical load were tested in the first experiment. The second study was conducted on a real-scale building compartment designed using corrugated web beams-concrete slab composite floor. The results obtained from experimental works reveal the real temperature distribution in the steel profile and the fire performance of sinusoidal corrugated web beams.
Název v anglickém jazyce
Beams with corrugated web at elevated temperature, experimental results
Popis výsledku anglicky
The paper is focused on presenting the thermal and mechanical response of sinusoidal corrugated web beams subjected to high temperatures. Two tests were performed to monitor the behavior of isolated elements and composite slabs designed with corrugated web beams. Different aspect ratio beams exposed to standard fire temperatures and one beam subjected also to mechanical load were tested in the first experiment. The second study was conducted on a real-scale building compartment designed using corrugated web beams-concrete slab composite floor. The results obtained from experimental works reveal the real temperature distribution in the steel profile and the fire performance of sinusoidal corrugated web beams.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-19073S" target="_blank" >GA15-19073S: Modely ocelobetonových sloupů s rozptýlenou výztuží při požáru</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Thin-Walled Structures
ISSN
0263-8231
e-ISSN
—
Svazek periodika
98
Číslo periodika v rámci svazku
2016
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
19-28
Kód UT WoS článku
000366767200003
EID výsledku v databázi Scopus
2-s2.0-84924975530