Influence of the heating and cooling rate on thermal performance of cement-lime plaster with PCM admixture
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00242670" target="_blank" >RIV/68407700:21110/16:00242670 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.677.150" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.677.150</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.677.150" target="_blank" >10.4028/www.scientific.net/KEM.677.150</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of the heating and cooling rate on thermal performance of cement-lime plaster with PCM admixture
Popis výsledku v původním jazyce
Thermal energy storage represents an important aspect of building energy conservation. Unfortunately, modern buildings with lightweight building envelopes not provide sufficient heat storage capacity and indoor overheating is a common problem, mostly solved by high performance air conditioning that leads to the higher electricity consumption. Here, Phase Change Materials (PCMs) that allow significant heat storage or release when undergo phase transition can find use. On this account, a detailed testing of a new type of cement-lime plaster modified by PCM admixture with respect to the temperature change rate is presented in the paper. The studied material is based on commercial dry plaster mixture that is modified by microencapsulated polymer PCM admixture. For characterization of the developed material, measurement of basic physical and mechanical properties is done. Within the DSC analysis, the researched material is exposed to the temperature loading ranging from 0 °C to 40 °C, with the temperature change rate of 1, 5 and 10 °C/min respectively. On the basis of DSC tests, temperature of phase change and its corresponding enthalpy are determined. The obtained data show the effect of heating and cooling mode on materials performance in the form of a significant shift of DSC curves. This effect is evaluated and applicability of incorporated PCM admixture for the use in thermal energy storage plasters is discussed.
Název v anglickém jazyce
Influence of the heating and cooling rate on thermal performance of cement-lime plaster with PCM admixture
Popis výsledku anglicky
Thermal energy storage represents an important aspect of building energy conservation. Unfortunately, modern buildings with lightweight building envelopes not provide sufficient heat storage capacity and indoor overheating is a common problem, mostly solved by high performance air conditioning that leads to the higher electricity consumption. Here, Phase Change Materials (PCMs) that allow significant heat storage or release when undergo phase transition can find use. On this account, a detailed testing of a new type of cement-lime plaster modified by PCM admixture with respect to the temperature change rate is presented in the paper. The studied material is based on commercial dry plaster mixture that is modified by microencapsulated polymer PCM admixture. For characterization of the developed material, measurement of basic physical and mechanical properties is done. Within the DSC analysis, the researched material is exposed to the temperature loading ranging from 0 °C to 40 °C, with the temperature change rate of 1, 5 and 10 °C/min respectively. On the basis of DSC tests, temperature of phase change and its corresponding enthalpy are determined. The obtained data show the effect of heating and cooling mode on materials performance in the form of a significant shift of DSC curves. This effect is evaluated and applicability of incorporated PCM admixture for the use in thermal energy storage plasters is discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-22909S" target="_blank" >GA14-22909S: Výzkum využití materiálů s fázovou změnou v tepelně akumulačních omítkách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Special Concrete and Composites 2015
ISBN
978-3-03835-579-3
ISSN
1013-9826
e-ISSN
—
Počet stran výsledku
5
Strana od-do
150-154
Název nakladatele
Trans Tech Publications
Místo vydání
Zurich
Místo konání akce
Skalský Dvůr
Datum konání akce
15. 10. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—