Popis výsledku v původním jazyce
New requirements for the design of light timber frames (fire resistance, high thermal resistance, composition of modern walls) lead to the necessity to perform static analysis of walls with one-sided board sheathing. The reinforcement of the panel (stud) is provided by means of glued timber composite I-shaped element consisting of a web made of a wood-based desk embedded into flanges of solid or glued laminated timber. The stability of the wall panels is usually ensured by sided board sheathing, which prevents buckling of studs in the plane of the wall or their twist. Walls with one-side board sheathing are used for some types of modern timber structures and their load bearing capacity is determined for situation when one-side sheathing burns during fire or sheathing is not made of a load-bearing material.
Název v anglickém jazyce
Hybrid Panels with I-shaped Stiffeners
Popis výsledku anglicky
New requirements for the design of light timber frames (fire resistance, high thermal resistance, composition of modern walls) lead to the necessity to perform static analysis of walls with one-sided board sheathing. The reinforcement of the panel (stud) is provided by means of glued timber composite I-shaped element consisting of a web made of a wood-based desk embedded into flanges of solid or glued laminated timber. The stability of the wall panels is usually ensured by sided board sheathing, which prevents buckling of studs in the plane of the wall or their twist. Walls with one-side board sheathing are used for some types of modern timber structures and their load bearing capacity is determined for situation when one-side sheathing burns during fire or sheathing is not made of a load-bearing material.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1605" target="_blank" >LO1605: Univerzitní centrum energeticky efektivních budov – Fáze udržitelnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Central Europe towards Sustainable Building 2016 - Innovations for Sustainable Future
ISBN
978-80-271-0248-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1030-1035
Název nakladatele
GRADA PUBLISHING
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
22. 6. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—