Laboratory testing of a building envelope segment based on cellular concrete
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00300516" target="_blank" >RIV/68407700:21110/16:00300516 - isvavai.cz</a>
Výsledek na webu
<a href="http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4955236;jsessionid=AXTzozETsFmmni_KxTzhCIth.x-aip-live-06" target="_blank" >http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4955236;jsessionid=AXTzozETsFmmni_KxTzhCIth.x-aip-live-06</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4955236" target="_blank" >10.1063/1.4955236</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laboratory testing of a building envelope segment based on cellular concrete
Popis výsledku v původním jazyce
Hygrothermal performance of a building envelope based on cellular concrete blocks is studied in the paper. Simultaneously, the strain fields induced by the heat and moisture changes are monitored. The studied wall is exposed to the climatic load corresponding to the winter climatic conditions of the moderate year for Prague. The winter climatic exposure is chosen in order to simulate the critical conditions of the building structure from the point of view of material performance and temperature and humidity loading. The evaluation of hygrothermal performance of a researched wall is done on the basis of relative humidity and temperature profiles measured along the cross section of the cellular concrete blocks. Strain gauges are fixed on the wall surface in expected orientation of the blocks expansion. The obtained results show a good hygrothermal function of the analyzed cellular concrete wall and its insignificant strain.
Název v anglickém jazyce
Laboratory testing of a building envelope segment based on cellular concrete
Popis výsledku anglicky
Hygrothermal performance of a building envelope based on cellular concrete blocks is studied in the paper. Simultaneously, the strain fields induced by the heat and moisture changes are monitored. The studied wall is exposed to the climatic load corresponding to the winter climatic conditions of the moderate year for Prague. The winter climatic exposure is chosen in order to simulate the critical conditions of the building structure from the point of view of material performance and temperature and humidity loading. The evaluation of hygrothermal performance of a researched wall is done on the basis of relative humidity and temperature profiles measured along the cross section of the cellular concrete blocks. Strain gauges are fixed on the wall surface in expected orientation of the blocks expansion. The obtained results show a good hygrothermal function of the analyzed cellular concrete wall and its insignificant strain.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP105%2F12%2FG059" target="_blank" >GBP105/12/G059: Kumulativní časově závislé procesy ve stavebních materiálech a konstrukcích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
THERMOPHYSICS 2016: 21ST INTERNATIONAL MEETING
ISBN
978-0-7354-1410-5
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
AIP Publishing, APL, the American Institute of Physics
Místo vydání
Melville, NY
Místo konání akce
Terchová
Datum konání akce
12. 10. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000380816400008