Ventilated underground tunnel as a contribution for sustainable refurbishment of buildings affected by rising moisture
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00300549" target="_blank" >RIV/68407700:21110/16:00300549 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ventilated underground tunnel as a contribution for sustainable refurbishment of buildings affected by rising moisture
Popis výsledku v původním jazyce
Additional protection of ground part of older buildings against subsurface water and ground moisture is one of the most important measures to ensure their long-time durability and satisfactory user properties. One of the most used remediation method are air ducts which principle is to enable an air flow along the surface of moist structures and to ensure sufficient evaporation of moisture from the structure. A special type of this method is underground ventilated tunnel situated along the perimeter walls. This technical solution allows there mediation of historic buildingsbecause it does not interfere in the building structure and does not modify the appearance of the building. The problem is, however, that the contemporary structural design of the ventilated tunnels is based on the masonry structure which does not have a sufficient durability and it is also laborious. The paper introduces a new technical solution of this method based on the special shaped concrete blocks with crystalline admixture used inside the concrete structure. This solution is structurally simple (low labor difficulty) and also highly durable. The efficiency of the method is demonstrated by the results of the laboratory tests, moisture is measured by electrical resistivity method.
Název v anglickém jazyce
Ventilated underground tunnel as a contribution for sustainable refurbishment of buildings affected by rising moisture
Popis výsledku anglicky
Additional protection of ground part of older buildings against subsurface water and ground moisture is one of the most important measures to ensure their long-time durability and satisfactory user properties. One of the most used remediation method are air ducts which principle is to enable an air flow along the surface of moist structures and to ensure sufficient evaporation of moisture from the structure. A special type of this method is underground ventilated tunnel situated along the perimeter walls. This technical solution allows there mediation of historic buildingsbecause it does not interfere in the building structure and does not modify the appearance of the building. The problem is, however, that the contemporary structural design of the ventilated tunnels is based on the masonry structure which does not have a sufficient durability and it is also laborious. The paper introduces a new technical solution of this method based on the special shaped concrete blocks with crystalline admixture used inside the concrete structure. This solution is structurally simple (low labor difficulty) and also highly durable. The efficiency of the method is demonstrated by the results of the laboratory tests, moisture is measured by electrical resistivity method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Central Europe towards Sustainable Building 2016 - Innovations for Sustainable Future
ISBN
978-80-271-0248-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
253-260
Název nakladatele
GRADA PUBLISHING
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
22. 6. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—