Measuring of Equivalent Air Layer Thickness of Nanofiber Textiles
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00301364" target="_blank" >RIV/68407700:21110/16:00301364 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.714.192" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.714.192</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.714.192" target="_blank" >10.4028/www.scientific.net/KEM.714.192</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measuring of Equivalent Air Layer Thickness of Nanofiber Textiles
Popis výsledku v původním jazyce
This article deals with selecting the appropriate method of measurement water vapour diffusion through nanofiber textiles. Parameter for comparison of different sheet materials for its ability to brake the water vapour is a equivalent air layer thickness value Sd. The equivalent air layer thickness Sd [m] expresses the equivalent air layer thickness of the air layer, which would have the same diffusion resistance as the thickness of the measured material. It is necessary to choose the appropriate measurement method for determining the value Sd with diffusion open materials such as nanofiber materials. This article compares the outcomes of two measurement methods – Dry Cup Method and Tube Method. The measurements were carried out on a sample from nanofiber textiles based on PVDF.
Název v anglickém jazyce
Measuring of Equivalent Air Layer Thickness of Nanofiber Textiles
Popis výsledku anglicky
This article deals with selecting the appropriate method of measurement water vapour diffusion through nanofiber textiles. Parameter for comparison of different sheet materials for its ability to brake the water vapour is a equivalent air layer thickness value Sd. The equivalent air layer thickness Sd [m] expresses the equivalent air layer thickness of the air layer, which would have the same diffusion resistance as the thickness of the measured material. It is necessary to choose the appropriate measurement method for determining the value Sd with diffusion open materials such as nanofiber materials. This article compares the outcomes of two measurement methods – Dry Cup Method and Tube Method. The measurements were carried out on a sample from nanofiber textiles based on PVDF.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP14-04431P" target="_blank" >GP14-04431P: Ochranné vrstvy na bázi polymerních nanovláken</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 17th Conference on the Rehabilitation and Reconstruction of Buildings (CRRB 2015)
ISBN
978-3-03835-719-3
ISSN
1013-9826
e-ISSN
—
Počet stran výsledku
4
Strana od-do
192-195
Název nakladatele
Trans Tech Publications Inc.
Místo vydání
Pfaffikon
Místo konání akce
Praha
Datum konání akce
12. 11. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—