The paper deals with experimental investigation of drying and shrinkage of concrete in large concrete specimens. The segments of walls of the thickness 200 mm, 400 mm and 800 mm were cast. Four sides were sealed so that the drying of the infinite walls of different thicknesses could be simulated and the size effect could be captured. The relative pore humidity is measured in different distances from the surface of individual walls. 4 vibrating wire strain gauges are embedded inside the elements which measure strains in horizontal and vertical directions. The relative pore humidity and the strains have been recorded for the period of 1 year. The segments of the walls are stored in a laboratory. Relative humidity and temperature of the environment could not be controlled; they are recorded very closely. Additional tests on laboratory specimens have been executed. The experiments have pointed out the necessity to measure strains in concrete from the early-age.
Název v anglickém jazyce
Drying and Shrinkage of Large Concrete Specimens
Popis výsledku anglicky
The paper deals with experimental investigation of drying and shrinkage of concrete in large concrete specimens. The segments of walls of the thickness 200 mm, 400 mm and 800 mm were cast. Four sides were sealed so that the drying of the infinite walls of different thicknesses could be simulated and the size effect could be captured. The relative pore humidity is measured in different distances from the surface of individual walls. 4 vibrating wire strain gauges are embedded inside the elements which measure strains in horizontal and vertical directions. The relative pore humidity and the strains have been recorded for the period of 1 year. The segments of the walls are stored in a laboratory. Relative humidity and temperature of the environment could not be controlled; they are recorded very closely. Additional tests on laboratory specimens have been executed. The experiments have pointed out the necessity to measure strains in concrete from the early-age.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Performance -Based Approaches for Concrete Structures. Proceedings: Extended Abstracts and Keynotes
ISBN
978-2-88394-120-5
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
University of Cape Town
Místo vydání
Cape Town
Místo konání akce
Cape Town
Datum konání akce
21. 11. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—