Influence of Steel Fibres in Steel Fibre Reinforced Concrete on ULS and SLS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F16%3A00307300" target="_blank" >RIV/68407700:21110/16:00307300 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Steel Fibres in Steel Fibre Reinforced Concrete on ULS and SLS
Popis výsledku v původním jazyce
The paper presents the influence of steel fibres in the steel fibre reinforced concrete on ultimate limit state and serviceability limit state of the load-bearing constructions. The paper is limited only to the bending load bearing capacity from ULS point of view and limited only to vertical deformation from SLS point of view. The practical example is a part of paper – the calculation of two bending constructions. Firstly, it is calculated as the construction of ordinary concrete reinforced steel armature and secondly it is calculated as the construction of steel fibre reinforced concrete reinforced steel reinforcement. The geometric arrangement, the type and the quantity of reinforcement are identical for both calculated structures. The calculated structures are different only in the tensile strength by the limit of formation of a macro crack and the residual tensile strength. All other input parameters are identical for both calculated structures, in order the influence of tensile strength on ULS and SLS excels.
Název v anglickém jazyce
Influence of Steel Fibres in Steel Fibre Reinforced Concrete on ULS and SLS
Popis výsledku anglicky
The paper presents the influence of steel fibres in the steel fibre reinforced concrete on ultimate limit state and serviceability limit state of the load-bearing constructions. The paper is limited only to the bending load bearing capacity from ULS point of view and limited only to vertical deformation from SLS point of view. The practical example is a part of paper – the calculation of two bending constructions. Firstly, it is calculated as the construction of ordinary concrete reinforced steel armature and secondly it is calculated as the construction of steel fibre reinforced concrete reinforced steel reinforcement. The geometric arrangement, the type and the quantity of reinforcement are identical for both calculated structures. The calculated structures are different only in the tensile strength by the limit of formation of a macro crack and the residual tensile strength. All other input parameters are identical for both calculated structures, in order the influence of tensile strength on ULS and SLS excels.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů