Chapel of Cemetery Church of All Saints in Sedlec – Long-Term Analysis of Hygrothermal Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00312759" target="_blank" >RIV/68407700:21110/17:00312759 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21610/17:00312759
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4994509" target="_blank" >http://dx.doi.org/10.1063/1.4994509</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4994509" target="_blank" >10.1063/1.4994509</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Chapel of Cemetery Church of All Saints in Sedlec – Long-Term Analysis of Hygrothermal Conditions
Popis výsledku v původním jazyce
In this paper, long-term monitoring of hygrothermal conditions of the chapel of the cemetery church of All Saints in Sedlec, Czech Republic is presented as a practical tool for evaluation of functional problems of the researched structure. Within the performed experimental tests, interior and exterior climatic conditions were monitored over one year period. Herewith, surface temperature of the chapel wall was measured. Exterior climatic data were collected using weather station Vantage Pro2 placed in church tower. In interior, precise combined relative humidity/temperature sensors were installed. Based on the accessed hygrothermal state of the inspected chapel and identified periods of possible surface condensation, service conditions of the chapel will be optimized in order to prevent extensive damage of historically valuable finishing and furnishing materials, paintings, plasters, and architectural ornaments.
Název v anglickém jazyce
Chapel of Cemetery Church of All Saints in Sedlec – Long-Term Analysis of Hygrothermal Conditions
Popis výsledku anglicky
In this paper, long-term monitoring of hygrothermal conditions of the chapel of the cemetery church of All Saints in Sedlec, Czech Republic is presented as a practical tool for evaluation of functional problems of the researched structure. Within the performed experimental tests, interior and exterior climatic conditions were monitored over one year period. Herewith, surface temperature of the chapel wall was measured. Exterior climatic data were collected using weather station Vantage Pro2 placed in church tower. In interior, precise combined relative humidity/temperature sensors were installed. Based on the accessed hygrothermal state of the inspected chapel and identified periods of possible surface condensation, service conditions of the chapel will be optimized in order to prevent extensive damage of historically valuable finishing and furnishing materials, paintings, plasters, and architectural ornaments.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP105%2F12%2FG059" target="_blank" >GBP105/12/G059: Kumulativní časově závislé procesy ve stavebních materiálech a konstrukcích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
THERMOPHYSICS 2017: 22nd International Meeting of Thermophysics 2017 and 4th Meeting of EnRe 2017
ISBN
978-0-7354-1546-1
ISSN
—
e-ISSN
1551-7616
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
American Institute of Physic AIP
Místo vydání
Santa Fe
Místo konání akce
Těrchová
Datum konání akce
12. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000426600400034