Moisture Buffer Capacity of Cement-Lime Plasters with Enhanced Thermal Storage Capacity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00313555" target="_blank" >RIV/68407700:21110/17:00313555 - isvavai.cz</a>
Výsledek na webu
<a href="http://aip.scitation.org/doi/abs/10.1063/1.4992334" target="_blank" >http://aip.scitation.org/doi/abs/10.1063/1.4992334</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4992334" target="_blank" >10.1063/1.4992334</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Moisture Buffer Capacity of Cement-Lime Plasters with Enhanced Thermal Storage Capacity
Popis výsledku v původním jazyce
Indoor air temperature and relative humidity represent important parameters for health and working efficiency of buildings occupants. Beside the moderation of temperature, investigation of hygric properties of building materials with connection to indoor relative humidity variation became recognized as a relevant factor for energy efficient building maintenance. The moisture buffer value introduced in the Nordtest protocol can be used for estimation of moisture buffer capacity of building materials or their multi-layered systems. In this paper, both the ideal and real moisture buffer values are examined on the basis of simulation of diurnal relative humidity fluctuations in plasters with incorporated PCM admixture. Retrieved data points to a complex effect of the tested plasters on possible moderation of buildings interior climate.
Název v anglickém jazyce
Moisture Buffer Capacity of Cement-Lime Plasters with Enhanced Thermal Storage Capacity
Popis výsledku anglicky
Indoor air temperature and relative humidity represent important parameters for health and working efficiency of buildings occupants. Beside the moderation of temperature, investigation of hygric properties of building materials with connection to indoor relative humidity variation became recognized as a relevant factor for energy efficient building maintenance. The moisture buffer value introduced in the Nordtest protocol can be used for estimation of moisture buffer capacity of building materials or their multi-layered systems. In this paper, both the ideal and real moisture buffer values are examined on the basis of simulation of diurnal relative humidity fluctuations in plasters with incorporated PCM admixture. Retrieved data points to a complex effect of the tested plasters on possible moderation of buildings interior climate.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-22909S" target="_blank" >GA14-22909S: Výzkum využití materiálů s fázovou změnou v tepelně akumulačních omítkách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of International Conference on Numerical Analysis and Applied Mathematics 2016 (ICNAAM-2016)
ISBN
978-0-7354-1538-6
ISSN
—
e-ISSN
0094-243X
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
AIP Conference Proceedings
Místo vydání
New York
Místo konání akce
Rhodes
Datum konání akce
19. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000410159800178