Popis výsledku v původním jazyce
Long-term deformations of the concrete are important for determination of behavior of concrete structures. For prediction of the long-term deformations rheological models are used. The models are usually derived from measurements on laboratory specimens. There are only few measurements performed on real structures. The objective of the realized experimental program is to compare predicted values of strains and strains measured on a real structure. Vibrating wire strain gauges have been installed in two columns in underground floors of eight-storey office building. Target of this paper is evaluation of measurement from the initial period (7 to 8 months). Measured values have been compared with results of first calculations and with values measured on laboratory specimens placed at the construction site.
Název v anglickém jazyce
Long-Term Monitoring of Concrete Building Structure
Popis výsledku anglicky
Long-term deformations of the concrete are important for determination of behavior of concrete structures. For prediction of the long-term deformations rheological models are used. The models are usually derived from measurements on laboratory specimens. There are only few measurements performed on real structures. The objective of the realized experimental program is to compare predicted values of strains and strains measured on a real structure. Vibrating wire strain gauges have been installed in two columns in underground floors of eight-storey office building. Target of this paper is evaluation of measurement from the initial period (7 to 8 months). Measured values have been compared with results of first calculations and with values measured on laboratory specimens placed at the construction site.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Solid State Phenomena
ISBN
978-3-0357-1284-1
ISSN
1662-9779
e-ISSN
—
Počet stran výsledku
6
Strana od-do
160-165
Název nakladatele
Trans Tech Publications
Místo vydání
Uetikon-Zurich
Místo konání akce
Litomyšl
Datum konání akce
22. 11. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—