Experimental Assessment of Separation Distances of a Load-Bearing Straw-Bale Construction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F18%3A00323158" target="_blank" >RIV/68407700:21110/18:00323158 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/18:00323158
Výsledek na webu
<a href="http://iopscience.iop.org/article/10.1088/1742-6596/1107/4/042013/pdf" target="_blank" >http://iopscience.iop.org/article/10.1088/1742-6596/1107/4/042013/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/1107/4/042013" target="_blank" >10.1088/1742-6596/1107/4/042013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental Assessment of Separation Distances of a Load-Bearing Straw-Bale Construction
Popis výsledku v původním jazyce
With an increasingly dense urban structure and wider use of energy efficient and combustible materials, the requirements on fire separation distances are becoming an actual topic. In the Czech Republic, separation distances are determined according to “fire openness” categorisation of external walls. In line with the Czech Fire Standards, combustible external walls must be considered as unprotected areas (fire opened areas) until the opposite is proven. This classification might be a crucial element in building design and for location of an object on a plot. This paper introduces a project on fire safety evaluation of a load-bearing straw-bale construction and focuses on experimental determination of fire openness of combustible external walls with incombustible surface (A1/A2 reaction to fire class). To assess fire risk and a contribution to fire growth and flame spread of the walls, a full-scale fire test of an experimental straw-bale house was carried out in September 2017. The experimental object was designed as a mock-up of a residential house, single-storey, stand-alone building with ground floor dimensions of 4.0 x 6.0 m and a height of 3.5 m with two symmetrical connected rooms. The observations and measurements showed that the experimental wall composition, even though it was not certified as a construction with a specific fire resistance, did not contribute to the fire propagation and could be assumed as a fire closed area, where as unprotected areas are considered only windows. In the case of the evaluated object, this classification leads to a reduction in separation distances of almost 4 meters. According to the results can be concluded that a different approach to evaluate fire openness could be desirable to establish.
Název v anglickém jazyce
Experimental Assessment of Separation Distances of a Load-Bearing Straw-Bale Construction
Popis výsledku anglicky
With an increasingly dense urban structure and wider use of energy efficient and combustible materials, the requirements on fire separation distances are becoming an actual topic. In the Czech Republic, separation distances are determined according to “fire openness” categorisation of external walls. In line with the Czech Fire Standards, combustible external walls must be considered as unprotected areas (fire opened areas) until the opposite is proven. This classification might be a crucial element in building design and for location of an object on a plot. This paper introduces a project on fire safety evaluation of a load-bearing straw-bale construction and focuses on experimental determination of fire openness of combustible external walls with incombustible surface (A1/A2 reaction to fire class). To assess fire risk and a contribution to fire growth and flame spread of the walls, a full-scale fire test of an experimental straw-bale house was carried out in September 2017. The experimental object was designed as a mock-up of a residential house, single-storey, stand-alone building with ground floor dimensions of 4.0 x 6.0 m and a height of 3.5 m with two symmetrical connected rooms. The observations and measurements showed that the experimental wall composition, even though it was not certified as a construction with a specific fire resistance, did not contribute to the fire propagation and could be assumed as a fire closed area, where as unprotected areas are considered only windows. In the case of the evaluated object, this classification leads to a reduction in separation distances of almost 4 meters. According to the results can be concluded that a different approach to evaluate fire openness could be desirable to establish.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Journal of Physics: Conference Series: Proceedings of the 3rd European symposium on fire safety sciences (ESFSS2018)
ISBN
—
ISSN
1742-6588
e-ISSN
1742-6596
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Institute of Physics Publishing
Místo vydání
Bristol
Místo konání akce
Nancy
Datum konání akce
12. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—