Effect of Moisture Variations on Damage Cumulation in Surface Layers of Building Structures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F18%3A00324327" target="_blank" >RIV/68407700:21110/18:00324327 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.5043730" target="_blank" >http://dx.doi.org/10.1063/1.5043730</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5043730" target="_blank" >10.1063/1.5043730</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of Moisture Variations on Damage Cumulation in Surface Layers of Building Structures
Popis výsledku v původním jazyce
A compatibility of materials involved in building envelope is very important from the point of view of their durability. Different hygric straining of particular materials upon exposure to weather conditions might be one of the factors leading to damage cumulation in surface layers. In this paper, a computational model of coupled heat, moisture and momentum transport is employed to assess damage cumulation in a selected detail of building envelope. Being based on experimentally determined material parameters, this model seems to be the optimal tool for the assessment of compatibility of materials. The compatibility of lime-cement plaster and autoclaved aerated concrete was shown to be suitable. The highest displacements reached only ~3.0.10-5 m which did not induce any damage within the investigated period.
Název v anglickém jazyce
Effect of Moisture Variations on Damage Cumulation in Surface Layers of Building Structures
Popis výsledku anglicky
A compatibility of materials involved in building envelope is very important from the point of view of their durability. Different hygric straining of particular materials upon exposure to weather conditions might be one of the factors leading to damage cumulation in surface layers. In this paper, a computational model of coupled heat, moisture and momentum transport is employed to assess damage cumulation in a selected detail of building envelope. Being based on experimentally determined material parameters, this model seems to be the optimal tool for the assessment of compatibility of materials. The compatibility of lime-cement plaster and autoclaved aerated concrete was shown to be suitable. The highest displacements reached only ~3.0.10-5 m which did not induce any damage within the investigated period.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP105%2F12%2FG059" target="_blank" >GBP105/12/G059: Kumulativní časově závislé procesy ve stavebních materiálech a konstrukcích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of International Conference on Numerical Analysis and Applied Mathematics 2017 (ICNAAM-2017)
ISBN
978-0-7354-1690-1
ISSN
—
e-ISSN
0094-243X
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
AIP Conference Proceedings
Místo vydání
New York
Místo konání akce
Thessaloniki
Datum konání akce
25. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000445105400079