The paper presents the problem of unsatisfactory indoor environmental quality in the Chapel of Holy Stairs in the north of the Czech Republic, which is represented by a high value of air moisture leading to the degradation of the historic interior and frescoes. In order to understand the overall hygro-thermal properties of the airflow in the chapel, monitoring of the air temperature and relative humidity in the chapel and the cloister was carried out. The monitoring data, which provides a basis for examining the initial condition of the Chapel, is used for the calibration of the numerical model developed within the current research. The model is created in a simplified form based on physical principles and the heat balance method. The numerical model enables one to find a suitable control algorithm for the adaptive ventilation system The main aim of this work is to present the benefits and limitations of adaptive ventilation. The analysis highlights the influence of the controlled air supply on the indoor environmental quality and the overall reduction in the amount of air moisture.
Název v anglickém jazyce
Adaptive Ventilation Towards Better IEQ: A Case Study of the Pilgrimage Chapel of Holy Stairs
Popis výsledku anglicky
The paper presents the problem of unsatisfactory indoor environmental quality in the Chapel of Holy Stairs in the north of the Czech Republic, which is represented by a high value of air moisture leading to the degradation of the historic interior and frescoes. In order to understand the overall hygro-thermal properties of the airflow in the chapel, monitoring of the air temperature and relative humidity in the chapel and the cloister was carried out. The monitoring data, which provides a basis for examining the initial condition of the Chapel, is used for the calibration of the numerical model developed within the current research. The model is created in a simplified form based on physical principles and the heat balance method. The numerical model enables one to find a suitable control algorithm for the adaptive ventilation system The main aim of this work is to present the benefits and limitations of adaptive ventilation. The analysis highlights the influence of the controlled air supply on the indoor environmental quality and the overall reduction in the amount of air moisture.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vytápění, větrání, instalace
ISSN
1210-1389
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
356-361
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—