Assessment of Separation Efficiency of Reconstructed Combined Sewer Overflow in Debr (Czech Republic)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00323594" target="_blank" >RIV/68407700:21110/19:00323594 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-99867-1_37" target="_blank" >http://dx.doi.org/10.1007/978-3-319-99867-1_37</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-99867-1_37" target="_blank" >10.1007/978-3-319-99867-1_37</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of Separation Efficiency of Reconstructed Combined Sewer Overflow in Debr (Czech Republic)
Popis výsledku v původním jazyce
This paper is aimed to assess the function of renovated combined sewer overflow (CSO) in Debr nad Jizerou. The former lateral CSO, which did not meet the requirements, was replaced with a modified type of tube CSO in 2012. The main goal of this study was to determine separation efficiency of the new CSO and to compare it to the previous situation. Monitoring itself included online observation of hydrological indicators in the sewer system, then continuous sampling during precipitation events and its assessment, moreover the chemical quality water judgment in recipient body in both immediate and long-term view. Comparing of current and older results, it is clear that the new CSO works better than the former CSO. The newly installed CSO decreases the pollution into the receiving body about 30-50% on average. Separation efficiency is improved and also values of the basic chemicals indicators in the recipient are better. Measuring on CSO showed the relevant correspondence of actual separation efficiency of suspended solids with the mathematical model.
Název v anglickém jazyce
Assessment of Separation Efficiency of Reconstructed Combined Sewer Overflow in Debr (Czech Republic)
Popis výsledku anglicky
This paper is aimed to assess the function of renovated combined sewer overflow (CSO) in Debr nad Jizerou. The former lateral CSO, which did not meet the requirements, was replaced with a modified type of tube CSO in 2012. The main goal of this study was to determine separation efficiency of the new CSO and to compare it to the previous situation. Monitoring itself included online observation of hydrological indicators in the sewer system, then continuous sampling during precipitation events and its assessment, moreover the chemical quality water judgment in recipient body in both immediate and long-term view. Comparing of current and older results, it is clear that the new CSO works better than the former CSO. The newly installed CSO decreases the pollution into the receiving body about 30-50% on average. Separation efficiency is improved and also values of the basic chemicals indicators in the recipient are better. Measuring on CSO showed the relevant correspondence of actual separation efficiency of suspended solids with the mathematical model.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20701 - Environmental and geological engineering, geotechnics
Návaznosti výsledku
Projekt
<a href="/cs/project/TE02000077" target="_blank" >TE02000077: Inteligentní Regiony - Informační modelování budov a sídel, technologie a infrastruktura pro udržitelný rozvoj</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
NEW TRENDS IN URBAN DRAINAGE MODELLING, UDM 2018
ISBN
978-3-319-99866-4
ISSN
1865-3529
e-ISSN
—
Počet stran výsledku
6
Strana od-do
224-229
Název nakladatele
Springer International Publishing
Místo vydání
Cham
Místo konání akce
Palermo
Datum konání akce
23. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000482068800037