Effect of the Personalized Ventilation to a Human Thermal Comfort
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00332059" target="_blank" >RIV/68407700:21110/19:00332059 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/19:00332059
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1755-1315/290/1/012146" target="_blank" >https://iopscience.iop.org/article/10.1088/1755-1315/290/1/012146</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1755-1315/290/1/012146" target="_blank" >10.1088/1755-1315/290/1/012146</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of the Personalized Ventilation to a Human Thermal Comfort
Popis výsledku v původním jazyce
The paper deals with effect of the personalized ventilation on thermal comfort of the human body. Especially the influence of different temperatures and velocities of the supply air provided by the personalized ventilation on sitting user during standard light office work. The goal is to figure out possible and comfortable range for the personalized ventilation system and to determine the maximum power of the device. For measurement we were using a prototype of the personalized ventilation system which is able to adjust temperature of the supply air using thermoelectric elements. A thermal manikin was used to simulate the human body and to measure the effect of the ventilation system to the human thermal comfort and the PIV (Particle Image Velocimetry) was used to measure vector field around the human body.
Název v anglickém jazyce
Effect of the Personalized Ventilation to a Human Thermal Comfort
Popis výsledku anglicky
The paper deals with effect of the personalized ventilation on thermal comfort of the human body. Especially the influence of different temperatures and velocities of the supply air provided by the personalized ventilation on sitting user during standard light office work. The goal is to figure out possible and comfortable range for the personalized ventilation system and to determine the maximum power of the device. For measurement we were using a prototype of the personalized ventilation system which is able to adjust temperature of the supply air using thermoelectric elements. A thermal manikin was used to simulate the human body and to measure the effect of the ventilation system to the human thermal comfort and the PIV (Particle Image Velocimetry) was used to measure vector field around the human body.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1605" target="_blank" >LO1605: Univerzitní centrum energeticky efektivních budov – Fáze udržitelnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Central Europe towards Sustainable Building (CESB19)
ISBN
—
ISSN
1755-1307
e-ISSN
1755-1315
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
IOP Publishing Ltd
Místo vydání
Bristol
Místo konání akce
Praha
Datum konání akce
2. 7. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—