ASSESMENT OF ADDITIONAL SHADING DEVICES INSTALLED ON G40 PREFAB HOUSES IN TERMS OF INDOOR ENVIRONMENT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00332565" target="_blank" >RIV/68407700:21110/19:00332565 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.5593/sgem2019/6.2/S27.048" target="_blank" >http://dx.doi.org/10.5593/sgem2019/6.2/S27.048</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5593/sgem2019/6.2/S27.048" target="_blank" >10.5593/sgem2019/6.2/S27.048</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ASSESMENT OF ADDITIONAL SHADING DEVICES INSTALLED ON G40 PREFAB HOUSES IN TERMS OF INDOOR ENVIRONMENT
Popis výsledku v původním jazyce
Nearly a third of Prague residential fund is represented by prefab houses built in the second half of the 20th century. Indoor environment quality in those houses does not meet current standards in many cases. Refurbishments in the past were mainly focused on reducing thermal losses in winter with insufficient attention to air ventilation or summer overheating. The article deals with a significant problem of high indoor temperatures during summer period present in G40 prefab houses. It evaluates an influence of several types of shading devices on indoor temperature of selected representative room with regard to daylight quality and air ventilation. A number of existing G40 buildings was studied to set an appropriate theoretical model of representative room. Prevailing window orientation, glazing type and building surroundings were considered as well as room air exchange. Influences of several sun-shading devices were assessed using Dial+. External louvers have proven to have the greatest impact on reducing indoor temperature with providing enough daylight at the same time. Unsolved overheating not only has negative impact on residents’ health and mental wellbeing, it may often lead to usage of air conditioning. Air cooling is three times more energy demanding than air heating, therefore it is not suitable in terms of EU policy of reducing energy consumption.
Název v anglickém jazyce
ASSESMENT OF ADDITIONAL SHADING DEVICES INSTALLED ON G40 PREFAB HOUSES IN TERMS OF INDOOR ENVIRONMENT
Popis výsledku anglicky
Nearly a third of Prague residential fund is represented by prefab houses built in the second half of the 20th century. Indoor environment quality in those houses does not meet current standards in many cases. Refurbishments in the past were mainly focused on reducing thermal losses in winter with insufficient attention to air ventilation or summer overheating. The article deals with a significant problem of high indoor temperatures during summer period present in G40 prefab houses. It evaluates an influence of several types of shading devices on indoor temperature of selected representative room with regard to daylight quality and air ventilation. A number of existing G40 buildings was studied to set an appropriate theoretical model of representative room. Prevailing window orientation, glazing type and building surroundings were considered as well as room air exchange. Influences of several sun-shading devices were assessed using Dial+. External louvers have proven to have the greatest impact on reducing indoor temperature with providing enough daylight at the same time. Unsolved overheating not only has negative impact on residents’ health and mental wellbeing, it may often lead to usage of air conditioning. Air cooling is three times more energy demanding than air heating, therefore it is not suitable in terms of EU policy of reducing energy consumption.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20103 - Architecture engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
19th International Multidisciplinary Scientific Geoconference SGEM 2019
ISBN
978-619-7408-89-8
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
7
Strana od-do
379-385
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Albena
Datum konání akce
30. 6. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—