Blast resistance of multi-layered concrete slabs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00333543" target="_blank" >RIV/68407700:21110/19:00333543 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1757-899X/596/1/012030/meta" target="_blank" >https://iopscience.iop.org/article/10.1088/1757-899X/596/1/012030/meta</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/596/1/012030" target="_blank" >10.1088/1757-899X/596/1/012030</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Blast resistance of multi-layered concrete slabs
Popis výsledku v původním jazyce
This paper compares blast resistance of multi-layered and single-layered concrete panels having different thickness and reinforcement and subjected to various explosive charges. The panels were analysed by ultrasound measurements before the application of blast loading; the velocity of transfer of ultrasound waves through the panels was determined. The same measurement was conducted after exposing the panels to contact explosion and the damage was evaluated based on the determined changes. Nine panels were tested, four of them single-layered and five of them multi-layered. The weights of Pentrite explosive charges were 150 g, 300 g and 500 g. The results show that multi-layered panels are suitable for the protection of soft targets or as cladding of load-bearing structures.
Název v anglickém jazyce
Blast resistance of multi-layered concrete slabs
Popis výsledku anglicky
This paper compares blast resistance of multi-layered and single-layered concrete panels having different thickness and reinforcement and subjected to various explosive charges. The panels were analysed by ultrasound measurements before the application of blast loading; the velocity of transfer of ultrasound waves through the panels was determined. The same measurement was conducted after exposing the panels to contact explosion and the damage was evaluated based on the determined changes. Nine panels were tested, four of them single-layered and five of them multi-layered. The weights of Pentrite explosive charges were 150 g, 300 g and 500 g. The results show that multi-layered panels are suitable for the protection of soft targets or as cladding of load-bearing structures.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TH02010888" target="_blank" >TH02010888: Posílení konkurenceschopnosti zvyšováním užitných vlastností prefabrikovaných konstrukčních prvků z ultra-vysokohodnotného betonu (UHPC)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Fibre Concrete 2019
ISBN
—
ISSN
1757-899X
e-ISSN
1757-899X
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
IOP Publishing Ltd
Místo vydání
Bristol
Místo konání akce
Praha
Datum konání akce
17. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—