SHEAR RESISTANCE OF SANDWICH PANEL CONNECTION TO THE SUBSTRUCTURE AT ELEVATED TEMPERATURE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00333654" target="_blank" >RIV/68407700:21110/19:00333654 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SHEAR RESISTANCE OF SANDWICH PANEL CONNECTION TO THE SUBSTRUCTURE AT ELEVATED TEMPERATURE
Popis výsledku v původním jazyce
Sandwich construction has developed and has become an integral part of lightweight construction. In the recent projects it has been shown that by using sandwich panels as a stabilizing members, a considerable amount of savings of steel can be achieved for structural members at ambient temperature. These stabilising effects may also help to achieve similar savings in case of fire.The response of single panel as well as the behaviour of whole structure is influenced by joints between sandwich panels and sub-structure. The fastenings used to fix the sandwich panels to a sub-structure, may be loaded by shear forces caused by self-weight, live loads or diaphragm action. Therefore, an experimental investigation was therefore conducted to investigate the shear behaviour of sandwich panel joints in fire when loaded in shear. This paper presents the experimental results on the shear behaviour of sandwich panel joints at ambient and elevated temperatures.
Název v anglickém jazyce
SHEAR RESISTANCE OF SANDWICH PANEL CONNECTION TO THE SUBSTRUCTURE AT ELEVATED TEMPERATURE
Popis výsledku anglicky
Sandwich construction has developed and has become an integral part of lightweight construction. In the recent projects it has been shown that by using sandwich panels as a stabilizing members, a considerable amount of savings of steel can be achieved for structural members at ambient temperature. These stabilising effects may also help to achieve similar savings in case of fire.The response of single panel as well as the behaviour of whole structure is influenced by joints between sandwich panels and sub-structure. The fastenings used to fix the sandwich panels to a sub-structure, may be loaded by shear forces caused by self-weight, live loads or diaphragm action. Therefore, an experimental investigation was therefore conducted to investigate the shear behaviour of sandwich panel joints in fire when loaded in shear. This paper presents the experimental results on the shear behaviour of sandwich panel joints at ambient and elevated temperatures.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of International Conference in Singapore, 13-14 June 2019
ISBN
—
ISSN
2336-7318
e-ISSN
2336-7318
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Nanyang Technological University
Datum konání akce
13. 6. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—