The possibility of utilization of sewage sludge as a filler in production of the lightweight aggregate concrete
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00334345" target="_blank" >RIV/68407700:21110/19:00334345 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1515/eces-2019-0041" target="_blank" >https://doi.org/10.1515/eces-2019-0041</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/eces-2019-0041" target="_blank" >10.1515/eces-2019-0041</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The possibility of utilization of sewage sludge as a filler in production of the lightweight aggregate concrete
Popis výsledku v původním jazyce
The article presents the laboratory investigations of the basic thermal and hygric parameters of standard lightweight aggregate-concrete and lightweight aggregate-concrete supplemented with municipal sewage sludge. Both types of concrete are based on light aggregates, commonly used in the Polish building market. In order to improve the hygric parameters of the material, such as water absorptivity, the admixture of water emulsion of reactive polisiloxanes was applied. Within the presented research, together with basic moisture parameters estimation, capillary rise process was monitored using Time Domain Reflectometry (TDR) modified sensors. Hygric parameters were supplemented with the estimation of thermal conductivity coefficient λ determined using stationary method. The analysis of thermal and hygric properties of concrete confirmed the applicability of lightweight aggregate-concrete with sewage sludge supplementation for further production.
Název v anglickém jazyce
The possibility of utilization of sewage sludge as a filler in production of the lightweight aggregate concrete
Popis výsledku anglicky
The article presents the laboratory investigations of the basic thermal and hygric parameters of standard lightweight aggregate-concrete and lightweight aggregate-concrete supplemented with municipal sewage sludge. Both types of concrete are based on light aggregates, commonly used in the Polish building market. In order to improve the hygric parameters of the material, such as water absorptivity, the admixture of water emulsion of reactive polisiloxanes was applied. Within the presented research, together with basic moisture parameters estimation, capillary rise process was monitored using Time Domain Reflectometry (TDR) modified sensors. Hygric parameters were supplemented with the estimation of thermal conductivity coefficient λ determined using stationary method. The analysis of thermal and hygric properties of concrete confirmed the applicability of lightweight aggregate-concrete with sewage sludge supplementation for further production.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ECOLOGICAL CHEMISTRY AND ENGINEERING S-CHEMIA I INZYNIERIA EKOLOGICZNA S
ISSN
1898-6196
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
12
Strana od-do
559-570
Kód UT WoS článku
000488769900011
EID výsledku v databázi Scopus
2-s2.0-85074602308