Evaluation of masonry grouting effectiveness using thermography and ultrasonic methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00339350" target="_blank" >RIV/68407700:21110/19:00339350 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.14311/CEJ.2019.04.0041" target="_blank" >https://doi.org/10.14311/CEJ.2019.04.0041</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CEJ.2019.04.0041" target="_blank" >10.14311/CEJ.2019.04.0041</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of masonry grouting effectiveness using thermography and ultrasonic methods
Popis výsledku v původním jazyce
One of the frequently used methods of stabilization and reinforcement of historic masonry is grouting, especially grouting of cracks and voids in masonry structures. Determination of the properties of the injected structure, both in terms of physico-mechanical properties (with regard to the subsequent compatibility of the grouting mixture) and in terms of its conditionand failures(cracks, voids, cavities), is a prerequisite for correct design and realization of reinforcement grouting. Minimization of interventions intothe historic structurewhile performingsurveys and the associated use of non-destructive diagnostic methods is one of the requirements forthe remediation of listed buildings. Within the experimental research of reinforcement of historic masonry structures, the possibility of using thermographyand ultrasound methods was evaluatedand conditions and limitations for the use of these non-destructive methods were formulated.
Název v anglickém jazyce
Evaluation of masonry grouting effectiveness using thermography and ultrasonic methods
Popis výsledku anglicky
One of the frequently used methods of stabilization and reinforcement of historic masonry is grouting, especially grouting of cracks and voids in masonry structures. Determination of the properties of the injected structure, both in terms of physico-mechanical properties (with regard to the subsequent compatibility of the grouting mixture) and in terms of its conditionand failures(cracks, voids, cavities), is a prerequisite for correct design and realization of reinforcement grouting. Minimization of interventions intothe historic structurewhile performingsurveys and the associated use of non-destructive diagnostic methods is one of the requirements forthe remediation of listed buildings. Within the experimental research of reinforcement of historic masonry structures, the possibility of using thermographyand ultrasound methods was evaluatedand conditions and limitations for the use of these non-destructive methods were formulated.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20103 - Architecture engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/DG16P02M055" target="_blank" >DG16P02M055: Vývoj a výzkum materiálů, postupů a technologií pro restaurování, konzervaci a zpevňování historických zděných konstrukcí a povrchů a systémů preventivní ochrany historických a památkově chráněných objektů ohrožených antropogenními a přírodními riziky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
The Civil Engineering Journal
ISSN
1210-4027
e-ISSN
1805-2576
Svazek periodika
4
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
506-516
Kód UT WoS článku
000504690000003
EID výsledku v databázi Scopus
—