Influence of the external pressure tap position on the airtightness test result
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00357283" target="_blank" >RIV/68407700:21110/19:00357283 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of the external pressure tap position on the airtightness test result
Popis výsledku v původním jazyce
Due to the wind induced pressure, different results may be obtained if the inside-outside pressure difference is measured across different locations on the building envelope, i.e. if the external pressure tap of a differential pressure sensor measuring this pressure difference is placed in different positions. Therefore, the position of the external pressure tap may influence an airtightness test result as well. As the wind induced pressure is linked with the wind speed, it can be expected that the influence of the external pressure tap position on the airtightness test result would be amplified with increasing wind speed. The aim of this full-scale experiment is to quantify the variability of the airtightness test results obtained under repeatability conditions with different external pressure tap positions in function of the wind speed. The motivation is a better understanding of the real influence of the wind allowing a better estimation of the measurement uncertainty as well as possible improvement of the measurement technique.
Název v anglickém jazyce
Influence of the external pressure tap position on the airtightness test result
Popis výsledku anglicky
Due to the wind induced pressure, different results may be obtained if the inside-outside pressure difference is measured across different locations on the building envelope, i.e. if the external pressure tap of a differential pressure sensor measuring this pressure difference is placed in different positions. Therefore, the position of the external pressure tap may influence an airtightness test result as well. As the wind induced pressure is linked with the wind speed, it can be expected that the influence of the external pressure tap position on the airtightness test result would be amplified with increasing wind speed. The aim of this full-scale experiment is to quantify the variability of the airtightness test results obtained under repeatability conditions with different external pressure tap positions in function of the wind speed. The motivation is a better understanding of the real influence of the wind allowing a better estimation of the measurement uncertainty as well as possible improvement of the measurement technique.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
40th AIVC Conference, 8th TightVent Conference, 6th venticool Conference, From energy crisis to sustainable indoor climate – 40 years of AIVC
ISBN
978-2-930471-56-3
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
704-705
Název nakladatele
AIVC INIVE EEIG
Místo vydání
Brussels
Místo konání akce
Gent
Datum konání akce
15. 10. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—