Experimental investigation of temperature and loading rate effects on the initial shear stiffness of polymeric interlayers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F20%3A00342150" target="_blank" >RIV/68407700:21110/20:00342150 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21610/20:00342150
Výsledek na webu
<a href="https://doi.org/10.1016/j.engstruct.2020.110728" target="_blank" >https://doi.org/10.1016/j.engstruct.2020.110728</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.engstruct.2020.110728" target="_blank" >10.1016/j.engstruct.2020.110728</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental investigation of temperature and loading rate effects on the initial shear stiffness of polymeric interlayers
Popis výsledku v původním jazyce
There are many examples of glass load bearing structures used in a contemporary architecture, such as panes, balustrades, and even stairs. For safety reasons, these structural elements are made of laminated glass which is a composition of glass plies bonded with polymeric interlayer. The distribution of stress in a perpendicularly loaded laminated glass panel depends on the shear stiffness of the used interlayer. There are various interlayers for laminated glass applications available on the market with wide variety of shear stiffness. To correctly evaluate the shear coupling provided by the interlayer, great research efforts have been made followed by appropriate national Standards and Codes for laminated glass in bending in recent years. Polymeric interlayers are viscoelastic materials and their stiffness is time and temperature dependent, which makes the reliable design of laminated glass panel in bending rather complicated. This paper is focused on experimental investigation of six polymeric interlayers (Trosifol® BG R20; Trosifol® Extra Strong; Evalam® 80/120; Evasafe®; SentryGlas® 5000; Krystalflex® PE399) loaded in displacement-controlled shear test in various temperatures and loading rates. The experiments showed nonlinear stress–strain dependence and confirmed the viscoelastic behaviour of presented interlayers. In addition, the values of their initial shear stiffness are listed and failure modes of testing specimens are presented. Results obtained in this study can be used for the estimation of the rate of glass plies interaction in short-term loaded laminated glass structures. All experiments were performed in Klokner Institute CTU.
Název v anglickém jazyce
Experimental investigation of temperature and loading rate effects on the initial shear stiffness of polymeric interlayers
Popis výsledku anglicky
There are many examples of glass load bearing structures used in a contemporary architecture, such as panes, balustrades, and even stairs. For safety reasons, these structural elements are made of laminated glass which is a composition of glass plies bonded with polymeric interlayer. The distribution of stress in a perpendicularly loaded laminated glass panel depends on the shear stiffness of the used interlayer. There are various interlayers for laminated glass applications available on the market with wide variety of shear stiffness. To correctly evaluate the shear coupling provided by the interlayer, great research efforts have been made followed by appropriate national Standards and Codes for laminated glass in bending in recent years. Polymeric interlayers are viscoelastic materials and their stiffness is time and temperature dependent, which makes the reliable design of laminated glass panel in bending rather complicated. This paper is focused on experimental investigation of six polymeric interlayers (Trosifol® BG R20; Trosifol® Extra Strong; Evalam® 80/120; Evasafe®; SentryGlas® 5000; Krystalflex® PE399) loaded in displacement-controlled shear test in various temperatures and loading rates. The experiments showed nonlinear stress–strain dependence and confirmed the viscoelastic behaviour of presented interlayers. In addition, the values of their initial shear stiffness are listed and failure modes of testing specimens are presented. Results obtained in this study can be used for the estimation of the rate of glass plies interaction in short-term loaded laminated glass structures. All experiments were performed in Klokner Institute CTU.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA18-10907S" target="_blank" >GA18-10907S: Mechanické vlastnosti polymerních lepených spojů pro aplikace ve stavebnictví s ohledem na působení okolního prostředí a stárnutí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Engineering Structures
ISSN
0141-0296
e-ISSN
1873-7323
Svazek periodika
223
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
—
Kód UT WoS článku
000576741000003
EID výsledku v databázi Scopus
2-s2.0-85089536348