Influence of Compression Pressure on Thermal Expansion, Bulk Density, and Porosity of Electroporcelain after Firing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F20%3A00342927" target="_blank" >RIV/68407700:21110/20:00342927 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1063/5.0025878" target="_blank" >https://doi.org/10.1063/5.0025878</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0025878" target="_blank" >10.1063/5.0025878</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Compression Pressure on Thermal Expansion, Bulk Density, and Porosity of Electroporcelain after Firing
Popis výsledku v původním jazyce
The influence of the compression pressure on the thermal expansion, bulk density, and porosity of electroporcelain type C 130 made under the pressures of 70 MPa, 90 MPa, and 110 MPa is studied after firing up to 1400 °C by a step of 100 °C. The mass loss and shrinkage of samples decreases with the compression pressure. The bulk density of the studied samples differs to a very little extent. At the firing temperature of 1400 °C, the lowest porosity is obtained for the sample pressed under the highest compression pressure. At 1300 °C, which is the common temperature for electroporcelain production, the lowest porosity is for the sample pressed at 90 MPa.
Název v anglickém jazyce
Influence of Compression Pressure on Thermal Expansion, Bulk Density, and Porosity of Electroporcelain after Firing
Popis výsledku anglicky
The influence of the compression pressure on the thermal expansion, bulk density, and porosity of electroporcelain type C 130 made under the pressures of 70 MPa, 90 MPa, and 110 MPa is studied after firing up to 1400 °C by a step of 100 °C. The mass loss and shrinkage of samples decreases with the compression pressure. The bulk density of the studied samples differs to a very little extent. At the firing temperature of 1400 °C, the lowest porosity is obtained for the sample pressed under the highest compression pressure. At 1300 °C, which is the common temperature for electroporcelain production, the lowest porosity is for the sample pressed at 90 MPa.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20504 - Ceramics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings 2275
ISBN
978-0-7354-4005-0
ISSN
—
e-ISSN
1551-7616
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
AIP Publishing, APL, the American Institute of Physics
Místo vydání
Melville, NY
Místo konání akce
Eger
Datum konání akce
2. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—