Is TDR method applicable for moisture content measurement in salt laden materials?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F20%3A00343892" target="_blank" >RIV/68407700:21110/20:00343892 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1063/5.0034631" target="_blank" >https://doi.org/10.1063/5.0034631</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0034631" target="_blank" >10.1063/5.0034631</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Is TDR method applicable for moisture content measurement in salt laden materials?
Popis výsledku v původním jazyce
Experimental investigation of the influence of salt presence on applicability of time domain reflectometry (TDR) method for moisture content measurement in porous materials was carried out in this study. The analysis was performed on calcium silicate material with the use of TDR-based device TDR/MUX/mts having rise time of about 250 ps. The measurement was conducted using advanced laboratory two-rod sensors. Finally, the obtained data of complex relative permittivity were assigned to the moisture content by reference gravimetric method within the calibration experiments where the penetrating medium was pure distilled water, 0.1 M and 0.01 M NaCl water solutions respectively. The acquired results demonstrated the applicability of high frequency microwave methods for moisture content measurement in porous building materials even in the case of presence of water soluble inorganic salts.
Název v anglickém jazyce
Is TDR method applicable for moisture content measurement in salt laden materials?
Popis výsledku anglicky
Experimental investigation of the influence of salt presence on applicability of time domain reflectometry (TDR) method for moisture content measurement in porous materials was carried out in this study. The analysis was performed on calcium silicate material with the use of TDR-based device TDR/MUX/mts having rise time of about 250 ps. The measurement was conducted using advanced laboratory two-rod sensors. Finally, the obtained data of complex relative permittivity were assigned to the moisture content by reference gravimetric method within the calibration experiments where the penetrating medium was pure distilled water, 0.1 M and 0.01 M NaCl water solutions respectively. The acquired results demonstrated the applicability of high frequency microwave methods for moisture content measurement in porous building materials even in the case of presence of water soluble inorganic salts.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Thermophysics 2020, 25th International Meeting
ISBN
978-0-7354-4041-8
ISSN
—
e-ISSN
0094-243X
Počet stran výsledku
4
Strana od-do
"02003-1"-"020013-4"
Název nakladatele
AIP Conference Proceedings
Místo vydání
New York
Místo konání akce
Smolenice
Datum konání akce
7. 9. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—