The sonic resonance method and the impulse excitation technique: A comparison study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F21%3A00353036" target="_blank" >RIV/68407700:21110/21:00353036 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/app112210802" target="_blank" >https://doi.org/10.3390/app112210802</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/app112210802" target="_blank" >10.3390/app112210802</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The sonic resonance method and the impulse excitation technique: A comparison study
Popis výsledku v původním jazyce
In this study, resonant frequencies of flexurally vibrating samples were measured using the sonic resonant method (SRM) and the impulse excitation technique (IET) to assess the equivalency of these two methods. Samples were made from different materials and with two shapes (prism with rectangular cross-section and cylinder with circular cross-section). The mean values and standard deviations of the resonant frequencies were compared using the t-test and the F-test. The tests showed an equivalency of both methods in measuring resonant frequency. The differences between the values measured using SRM and IET were not significant. Graphically, the relationship between the resonant frequencies is a line with a slope of 0.9993 ~ 1.
Název v anglickém jazyce
The sonic resonance method and the impulse excitation technique: A comparison study
Popis výsledku anglicky
In this study, resonant frequencies of flexurally vibrating samples were measured using the sonic resonant method (SRM) and the impulse excitation technique (IET) to assess the equivalency of these two methods. Samples were made from different materials and with two shapes (prism with rectangular cross-section and cylinder with circular cross-section). The mean values and standard deviations of the resonant frequencies were compared using the t-test and the F-test. The tests showed an equivalency of both methods in measuring resonant frequency. The differences between the values measured using SRM and IET were not significant. Graphically, the relationship between the resonant frequencies is a line with a slope of 0.9993 ~ 1.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10307 - Acoustics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Sciences
ISSN
2076-3417
e-ISSN
2076-3417
Svazek periodika
11
Číslo periodika v rámci svazku
22
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
9
Strana od-do
1-9
Kód UT WoS článku
000725912000001
EID výsledku v databázi Scopus
2-s2.0-85119615345