Method of Extending the Operation of Steam-Generator on Nuclear Installation under Conditions of Long-Term Station-Black-Out
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F21%3A00355740" target="_blank" >RIV/68407700:21110/21:00355740 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/21:00355740
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Method of Extending the Operation of Steam-Generator on Nuclear Installation under Conditions of Long-Term Station-Black-Out
Popis výsledku v původním jazyce
The accident at the Fukushima nuclear power plant has demonstrated new challenges for the safety management of a nuclear pow-er plants. The proposed measures aim is to avoid damage to the fuel cladding, which sooner or later will cause fission products to leak outside the nuclear power plant. The nuclear power plant steam generator is used at normal operation conditions to produce steam, which is used to drive the generator turbine. The article describes the long-term measures at accident associated with the loss of power supply from emergency diesel generators. It shows the way how the Feed & Bleed method will be used for removing the residual heat at the Temelin NPP in this case. This technique increases both, the robustness and the resilience; the operating time of the steam generator with coolant extends from 223 to 705, or up to 3500 hours.
Název v anglickém jazyce
Method of Extending the Operation of Steam-Generator on Nuclear Installation under Conditions of Long-Term Station-Black-Out
Popis výsledku anglicky
The accident at the Fukushima nuclear power plant has demonstrated new challenges for the safety management of a nuclear pow-er plants. The proposed measures aim is to avoid damage to the fuel cladding, which sooner or later will cause fission products to leak outside the nuclear power plant. The nuclear power plant steam generator is used at normal operation conditions to produce steam, which is used to drive the generator turbine. The article describes the long-term measures at accident associated with the loss of power supply from emergency diesel generators. It shows the way how the Feed & Bleed method will be used for removing the residual heat at the Temelin NPP in this case. This technique increases both, the robustness and the resilience; the operating time of the steam generator with coolant extends from 223 to 705, or up to 3500 hours.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 31st European Safety and Reliability Conference ESREL 2021
ISBN
978-981-18-2016-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
138-145
Název nakladatele
Research Publishing Services
Místo vydání
Singapore
Místo konání akce
Angers
Datum konání akce
19. 9. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—