Impact of Setting Retarder Incorporation on Foam Concrete Properties
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F22%3A00359909" target="_blank" >RIV/68407700:21110/22:00359909 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Impact of Setting Retarder Incorporation on Foam Concrete Properties
Popis výsledku v původním jazyce
This study deals with the low stability of the pre-made foam used for foam concrete manufacturing. Previously, it was observed that foam mixed with fresh concrete quickly deteriorates. Such a process in general results in insufficient foam concrete porosity. Based on a US patent, the following solution has been suggested: adding setting retarder into the concrete composition. Four sets of samples were manufactured – a reference sample and three samples containing 0.1, 0.3, and 0.4 wt. % of setting retarder. For those samples, bulk density, strength, and sound absorption were measured. Based on the obtained results, it was decided that setting retarder addition results in better foam stability and therefore in higher total porosity. The best results were provided by the sample containing 0.3 wt. % of retarder.
Název v anglickém jazyce
Impact of Setting Retarder Incorporation on Foam Concrete Properties
Popis výsledku anglicky
This study deals with the low stability of the pre-made foam used for foam concrete manufacturing. Previously, it was observed that foam mixed with fresh concrete quickly deteriorates. Such a process in general results in insufficient foam concrete porosity. Based on a US patent, the following solution has been suggested: adding setting retarder into the concrete composition. Four sets of samples were manufactured – a reference sample and three samples containing 0.1, 0.3, and 0.4 wt. % of setting retarder. For those samples, bulk density, strength, and sound absorption were measured. Based on the obtained results, it was decided that setting retarder addition results in better foam stability and therefore in higher total porosity. The best results were provided by the sample containing 0.3 wt. % of retarder.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FW03010173" target="_blank" >FW03010173: Vývoj zvukoabsorpčního betonu pro interiérové aplikace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of PhD Workshop, Department of Concrete and Masonry Structures 2022
ISBN
978-80-01-06989-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
17-21
Název nakladatele
katedra betonových a zděných konstrukcí
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
27. 5. 2022
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—