Flexural strength of fibre reinforced concrete in relation to the angle of magnetically orientated fibres
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F22%3A00362329" target="_blank" >RIV/68407700:21110/22:00362329 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/22:00362329
Výsledek na webu
<a href="https://doi.org/10.1051/matecconf/202236405017" target="_blank" >https://doi.org/10.1051/matecconf/202236405017</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/matecconf/202236405017" target="_blank" >10.1051/matecconf/202236405017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flexural strength of fibre reinforced concrete in relation to the angle of magnetically orientated fibres
Popis výsledku v původním jazyce
This paper focuses on high-performance fibre-reinforced concrete and its flexural strength concerning fibre orientation. The orientation is provided by a fully controlled special device. This device can align the fibres in fresh concrete using a magnetic field. The specimens are inserted into the device at different angles to ensure different fibre orientations concerning the longer side of the sample, which corresponds to the direction of the main tensile stresses. Specifically, angles of 0 °, 30 °, 60 ° and 90 ° are tested and compared with each other and with reference specimens that are not exposed to a magnetic field. All samples are measured by a non-destructive method. This method was developed in our previous research and is based on measuring the quality factor Q of a measuring coil using an impedance meter. The samples are inserted into a measuring coil connected to an impedance meter. Flexural strength is obtained from the results of a threepoint bending test. All samples are tested until complete failure.
Název v anglickém jazyce
Flexural strength of fibre reinforced concrete in relation to the angle of magnetically orientated fibres
Popis výsledku anglicky
This paper focuses on high-performance fibre-reinforced concrete and its flexural strength concerning fibre orientation. The orientation is provided by a fully controlled special device. This device can align the fibres in fresh concrete using a magnetic field. The specimens are inserted into the device at different angles to ensure different fibre orientations concerning the longer side of the sample, which corresponds to the direction of the main tensile stresses. Specifically, angles of 0 °, 30 °, 60 ° and 90 ° are tested and compared with each other and with reference specimens that are not exposed to a magnetic field. All samples are measured by a non-destructive method. This method was developed in our previous research and is based on measuring the quality factor Q of a measuring coil using an impedance meter. The samples are inserted into a measuring coil connected to an impedance meter. Flexural strength is obtained from the results of a threepoint bending test. All samples are tested until complete failure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-00624S" target="_blank" >GA20-00624S: Studie vlivu elektromagnetického pole na chování rozptýlené výztuže v cementovém kompozitu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MATEC Web of Conferences
ISBN
—
ISSN
2261-236X
e-ISSN
2261-236X
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
EDP Sciences - Web of Conferences
Místo vydání
Les Ulis Cedex A
Místo konání akce
Cape Town
Datum konání akce
3. 10. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—