Initial investigation of the relative humidity effect on the convective heat exchange using full-scale wind tunnel experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F24%3A00382510" target="_blank" >RIV/68407700:21110/24:00382510 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1742-6596/2911/1/012008" target="_blank" >https://doi.org/10.1088/1742-6596/2911/1/012008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/2911/1/012008" target="_blank" >10.1088/1742-6596/2911/1/012008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Initial investigation of the relative humidity effect on the convective heat exchange using full-scale wind tunnel experiments
Popis výsledku v původním jazyce
In this paper, an initial investigation of the effect of relative humidity on the rate of convective heat exchange is carried out. For this reason, a specific sample design was developed that was tested in the unique closed-circuit wind tunnel laboratory that allows for investigation of various environmental loads on full-scale samples. The analysis of experimental data indicated the relative humidity as a potential key factor with a sufficient level of significancy that may seriously affect the rate of convective heat exchange between sample surface and ambient air.
Název v anglickém jazyce
Initial investigation of the relative humidity effect on the convective heat exchange using full-scale wind tunnel experiments
Popis výsledku anglicky
In this paper, an initial investigation of the effect of relative humidity on the rate of convective heat exchange is carried out. For this reason, a specific sample design was developed that was tested in the unique closed-circuit wind tunnel laboratory that allows for investigation of various environmental loads on full-scale samples. The analysis of experimental data indicated the relative humidity as a potential key factor with a sufficient level of significancy that may seriously affect the rate of convective heat exchange between sample surface and ambient air.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-08786S" target="_blank" >GA22-08786S: Přenos tepla v mezních vrstvách při povrchu obvodových plášťů budov a jeho vliv na energetickou náročnost objektů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Journal of Physics: Conference Series 2911
ISBN
—
ISSN
1742-6588
e-ISSN
1742-6596
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IOP Publishing Ltd.
Místo vydání
Bristol
Místo konání akce
Miskolctapolca
Datum konání akce
4. 9. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—