Effect of Floor Finishing Materials on Impact Sound Pressure Level
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F24%3A00383375" target="_blank" >RIV/68407700:21110/24:00383375 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.czakustika.cz/misc/aklisty/27-14.pdf" target="_blank" >https://www.czakustika.cz/misc/aklisty/27-14.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of Floor Finishing Materials on Impact Sound Pressure Level
Popis výsledku v původním jazyce
In this paper, it is demonstrated by experimental measurement how the floor finishing material may affect the final values of normalized impact sound pressure level by adding different floor finishing materials to a typical floating floor system. The experiment was conducted for a residential building under construction with finished subfloors and floor finishing materials laid upon them. Field experimental measurements were performed according to technical standards ČSN EN ISO 717-2 and ČSN EN ISO 16283-2 in the sound insulation frequency range 100–3150 Hz, but also frequencies below 100 Hz (range between 50 and 100 Hz) were considered. As shown by the results, the adding of a floor finishing material usually has a positive effect on impact sound pressure level in the mid and high frequency range. This outcome was expected, but also it is obvious that the use of a vinyl flooring or a carpet as a floor finishing material is more effective in the attenuation of impact sound pressure level than the use of a laminate flooring or floor tiling. Moreover, the experimental measurement proved that the amplification of impact sound pressure level on lower frequencies is an issue in many cases unavoidable with present knowledge and technology.
Název v anglickém jazyce
Effect of Floor Finishing Materials on Impact Sound Pressure Level
Popis výsledku anglicky
In this paper, it is demonstrated by experimental measurement how the floor finishing material may affect the final values of normalized impact sound pressure level by adding different floor finishing materials to a typical floating floor system. The experiment was conducted for a residential building under construction with finished subfloors and floor finishing materials laid upon them. Field experimental measurements were performed according to technical standards ČSN EN ISO 717-2 and ČSN EN ISO 16283-2 in the sound insulation frequency range 100–3150 Hz, but also frequencies below 100 Hz (range between 50 and 100 Hz) were considered. As shown by the results, the adding of a floor finishing material usually has a positive effect on impact sound pressure level in the mid and high frequency range. This outcome was expected, but also it is obvious that the use of a vinyl flooring or a carpet as a floor finishing material is more effective in the attenuation of impact sound pressure level than the use of a laminate flooring or floor tiling. Moreover, the experimental measurement proved that the amplification of impact sound pressure level on lower frequencies is an issue in many cases unavoidable with present knowledge and technology.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Akustické listy
ISSN
1212-4702
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
1-4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
13-20
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—