A Comparative Study of Indoor Accuracies Between SLAM and Static Scanners
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F25%3A00384662" target="_blank" >RIV/68407700:21110/25:00384662 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/app15148053" target="_blank" >https://doi.org/10.3390/app15148053</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/app15148053" target="_blank" >10.3390/app15148053</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Comparative Study of Indoor Accuracies Between SLAM and Static Scanners
Popis výsledku v původním jazyce
This study presents a comprehensive comparison of static and SLAM (Simultaneous Localization and Mapping) laser scanners of both new and old generation in a controlled indoor environment of a standard commercial building with long, linear corridors and recesses. The aim was to assess both global and local accuracy, as well as noise characteristics, of each scanner. Methods: A highly accurate static scanner was used to generate a reference point cloud. Five devices were evaluated: two static scanners (Leica RTC 360 and Trimble X7) and three SLAM scanners (GeoSLAM ZEB Horizon RT, Emesent Hovermap ST-X, and FARO Orbis). Accuracy analysis included systematic and random error assessment, axis-specific displacement evaluation, and profile-based local accuracy measurements. Additionally, noise was quantified before and after data smoothing. Static scanners yielded superior accuracies, with the Leica RTC 360 achieving the best performance (absolute accuracy of 1.2 mm). Among SLAM systems, the Emesent Hovermap ST-X and FARO Orbis-both newer-generation devices-demonstrated significant improvements over the older-generation GeoSLAM ZEB Horizon RT. After smoothing, the noise levels of these new-generation SLAM scanners (approx. 2.1-2.2 mm) approached those of static systems. The findings underline the ongoing technological progress in SLAM systems, with the new-generation SLAM scanners becoming increasingly viable alternatives to static scanners, especially when speed, ease of use, and reduced occlusions are prioritized. This makes them well-suited for rapid indoor mapping applications, provided that the slightly lower accuracy is acceptable for the intended use.
Název v anglickém jazyce
A Comparative Study of Indoor Accuracies Between SLAM and Static Scanners
Popis výsledku anglicky
This study presents a comprehensive comparison of static and SLAM (Simultaneous Localization and Mapping) laser scanners of both new and old generation in a controlled indoor environment of a standard commercial building with long, linear corridors and recesses. The aim was to assess both global and local accuracy, as well as noise characteristics, of each scanner. Methods: A highly accurate static scanner was used to generate a reference point cloud. Five devices were evaluated: two static scanners (Leica RTC 360 and Trimble X7) and three SLAM scanners (GeoSLAM ZEB Horizon RT, Emesent Hovermap ST-X, and FARO Orbis). Accuracy analysis included systematic and random error assessment, axis-specific displacement evaluation, and profile-based local accuracy measurements. Additionally, noise was quantified before and after data smoothing. Static scanners yielded superior accuracies, with the Leica RTC 360 achieving the best performance (absolute accuracy of 1.2 mm). Among SLAM systems, the Emesent Hovermap ST-X and FARO Orbis-both newer-generation devices-demonstrated significant improvements over the older-generation GeoSLAM ZEB Horizon RT. After smoothing, the noise levels of these new-generation SLAM scanners (approx. 2.1-2.2 mm) approached those of static systems. The findings underline the ongoing technological progress in SLAM systems, with the new-generation SLAM scanners becoming increasingly viable alternatives to static scanners, especially when speed, ease of use, and reduced occlusions are prioritized. This makes them well-suited for rapid indoor mapping applications, provided that the slightly lower accuracy is acceptable for the intended use.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Sciences
ISSN
2076-3417
e-ISSN
2076-3417
Svazek periodika
15
Číslo periodika v rámci svazku
14
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
24
Strana od-do
1-24
Kód UT WoS článku
001549332100001
EID výsledku v databázi Scopus
2-s2.0-105011688250