Medical Application of 3D Polymer Gel Dosimeter Evaluated by Nuclear Magnetic Resonance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F01%3A04066404" target="_blank" >RIV/68407700:21220/01:04066404 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Medical Application of 3D Polymer Gel Dosimeter Evaluated by Nuclear Magnetic Resonance
Popis výsledku v původním jazyce
The polymer-gel dosimeter is based on radiation-induced polymerization and cross-linking of acrylic monomers. The dosimeter is tissue equivalent and allows to measure 3-dimensional dose distributions. The formation of cross-linked polymers in the irradiated regions of the gel increases the nuclear magnetic resonance (NMR) relaxation rates of neighboring water protons. The purpose of this study was to test the use of BANG-2 type polymer-gel dosimeter for measurement of dose distribution in stereotactic radiosurgery with the Leksell gamma knife. BANG-2 type polymer-gel dosimeter was prepared. To obtain calibration curve (NMR 1/T2 response to absorbed dose) a few dosimeters were homogeneously irradiated by 60Co gamma photons in Gammacell 220 unit. To measure dose distribution from the Leksell gamma knife, testing flask filled by the gel was fixed in the head phantom and then irradiated based on calculated treatment plan. Experimentally obtained results from the irradiated phantom were co
Název v anglickém jazyce
Medical Application of 3D Polymer Gel Dosimeter Evaluated by Nuclear Magnetic Resonance
Popis výsledku anglicky
The polymer-gel dosimeter is based on radiation-induced polymerization and cross-linking of acrylic monomers. The dosimeter is tissue equivalent and allows to measure 3-dimensional dose distributions. The formation of cross-linked polymers in the irradiated regions of the gel increases the nuclear magnetic resonance (NMR) relaxation rates of neighboring water protons. The purpose of this study was to test the use of BANG-2 type polymer-gel dosimeter for measurement of dose distribution in stereotactic radiosurgery with the Leksell gamma knife. BANG-2 type polymer-gel dosimeter was prepared. To obtain calibration curve (NMR 1/T2 response to absorbed dose) a few dosimeters were homogeneously irradiated by 60Co gamma photons in Gammacell 220 unit. To measure dose distribution from the Leksell gamma knife, testing flask filled by the gel was fixed in the head phantom and then irradiated based on calculated treatment plan. Experimentally obtained results from the irradiated phantom were co
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The 13th International Conference on Solid State Dosimetry
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
64-64
Název nakladatele
National Technical University
Místo vydání
Athens
Místo konání akce
Athens
Datum konání akce
9. 8. 2001
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—