Determination of Near-to-Wall Distance in hot Wire Anemometry by a Theodolite
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F02%3A02076814" target="_blank" >RIV/68407700:21220/02:02076814 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Near-to-Wall Distance in hot Wire Anemometry by a Theodolite
Popis výsledku v původním jazyce
A theodolite with resolution power of one angle second was used. It was possible to fix the visual angle subtending the projection of the required small distance between the centre of the probe wire and the wall surface. A vertical straight-line drawn onthe wall surface parallelly along the traversation path facilitated aiming at the wall surface. The angle between the optic axis of the theodolite and the wall surface, 9.43o, the distance between the vertical axis of the theodolite and the straight-line drawn on the wall surface 2.38 m. The revolution of one angle second corresponded to a probe-to-wall distance of 0.012 mm. Due to possible error sources present the effective accuracy of the measurement was 0.01 mm.
Název v anglickém jazyce
Determination of Near-to-Wall Distance in hot Wire Anemometry by a Theodolite
Popis výsledku anglicky
A theodolite with resolution power of one angle second was used. It was possible to fix the visual angle subtending the projection of the required small distance between the centre of the probe wire and the wall surface. A vertical straight-line drawn onthe wall surface parallelly along the traversation path facilitated aiming at the wall surface. The angle between the optic axis of the theodolite and the wall surface, 9.43o, the distance between the vertical axis of the theodolite and the straight-line drawn on the wall surface 2.38 m. The revolution of one angle second corresponded to a probe-to-wall distance of 0.012 mm. Due to possible error sources present the effective accuracy of the measurement was 0.01 mm.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Workshop 2002
ISBN
80-01-02511-X
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
684-685
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
11. 2. 2002
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—